Chapter 15: LPC11U3x/2x/1x 16-bit counter/timers CT16B0/1
[1]
Reset value reflects the data stored in used bits only. It does not include reserved bits content.
Table 295. Register overview: 16-bit counter/timer 0 CT16B0 (base address 0x4000 C000)
Name
Access
Address
offset
Description
Reset
value
Reference
IR
R/W
0x000
Interrupt Register. The IR can be written to clear interrupts. The IR can
be read to identify which of eight possible interrupt sources are
pending.
0
TCR
R/W
0x004
Timer Control Register. The TCR is used to control the Timer Counter
functions. The Timer Counter can be disabled or reset through the
TCR.
0
TC
R/W
0x008
Timer Counter. The 16-bit TC is incremented every PR+1 cycles of
PCLK. The TC is controlled through the TCR.
0
PR
R/W
0x00C
Prescale Register. When the Prescale Counter (below) is equal to this
value, the next clock increments the TC and clears the PC.
0
PC
R/W
0x010
Prescale Counter. The 16-bit PC is a counter which is incremented to
the value stored in PR. When the value in PR is reached, the TC is
incremented and the PC is cleared. The PC is observable and
controllable through the bus interface.
0
MCR
R/W
0x014
Match Control Register. The MCR is used to control if an interrupt is
generated and if the TC is reset when a Match occurs.
0
MR0
R/W
0x018
Match Register 0. MR0 can be enabled through the MCR to reset the
TC, stop both the TC and PC, and/or generate an interrupt every time
MR0 matches the TC.
0
MR1
R/W
0x01C
Match Register 1. See MR0 description.
0
MR2
R/W
0x020
Match Register 2. See MR0 description.
0
MR3
R/W
0x024
Match Register 3. See MR0 description.
0
CCR
R/W
0x028
Capture Control Register. The CCR controls which edges of the
capture inputs are used to load the Capture Registers and whether or
not an interrupt is generated when a capture takes place.
0
CR0
RO
0x02C
Capture Register 0. CR0 is loaded with the value of TC when there is
an event on the CT16B0_CAP0 input.
0
-
-
0x030
Reserved.
-
-
CR1
RO
0x034
Capture Register 1. CR1 is loaded with the value of TC when there is
an event on the CT16B0_CAP1 input.
-
-
-
0x038
Reserved.
-
-
EMR
R/W
0x03C
External Match Register. The EMR controls the match function and
the external match pins CT16B0_MAT[1:0] and CT16B1_MAT[1:0].
0
-
-
0x040 -
0x06C
Reserved.
-
-
CTCR
R/W
0x070
Count Control Register. The CTCR selects between Timer and
Counter mode, and in Counter mode selects the signal and edge(s)
for counting.
0
PWMC
R/W
0x074
PWM Control Register. The PWMCON enables PWM mode for the
external match pins CT16B0_MAT[1:0] and CT16B1_MAT[1:0].
0