NXP Semiconductors
UM11526
KITFS5600FRDMEVM evaluation board
Name
Default
Description
J14
7−8 shorted
GPIO1 selection
•
1-2 → Floating
•
3-4 → GPO1
•
5-6 → ERRMON1
•
7-8 → VDDOTP (for debug and development)
J29
1−2 shorted
BIAS_IN selection
•
1-2 → Connect to ground
•
2-3 → BIAS_IN connected to J22. Apply 5.0 V on J22.
J30
1−2 shorted
VDDIO voltage selection
•
1-2 → 1.8 V
•
2-3 → 3.3 V
J32
1−2 shorted
VDDOTP Debug Selection
•
Closed → Apply debug voltage to VDDOTP
•
Open → Do not apply VDDOTP
J93
2−3 shorted
Select the source for VDDIO
•
1-2 shorted → VCC
•
2-3 shorted → LDO on board (see J30 for voltage selection)
J94
1−2 shorted
SW2 compensation selection
•
1-2 → 450 kHz operation
•
2-3 → 2.2 MHz operation
Table 1. Evaluation board jumper/switch descriptions
...continued
5.3 Schematic, board layout and bill of materials
The schematic, board layout and bill of materials for the KITFS5600FRDMEVM
evaluation board are available at
http://www.nxp.com/KITFS5600FRDMEVM
6 Installing and configuring software and tools
6.1 GUI installation
Unzip the
NXPGUI_PR_x
into any desired location. Find the
NXP_GUI_x.x-Setup
from
the GUI folder inside the package and run it to install the GUI in any desired location.
6.2 Freedom board firmware update
For Windows 10, disable the storage services: run services.msc; double-click on the
storage service from the list and press the Stop button.
UM11526
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2021. All rights reserved.
User manual
Rev. 1 — 25 May 2021