![NXP Semiconductors AN10881 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/nxp-semiconductors/an10881/an10881_application-note_1722199019.webp)
AN10881
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2011. All rights reserved.
Application note
Rev. 2 — 26 September 2011
19 of 102
NXP Semiconductors
AN10881
TEA1713 resonant power supply control IC with PFC
5.3.2 Block diagram for SUPIC start-up
5.3.3 Auxiliary winding on the HBC transformer
An auxiliary winding on the HBC transformer can be used to obtain a supply voltage for
SUPIC during operation. As SUPIC has a wide operational voltage range (15 V to 38 V),
this is not a critical parameter.
But:
•
The voltage on SUPIC must be low for low power consumption.
•
The auxiliary supply must be made accurately representing the output voltage to use
the voltage from the auxiliary winding for IC supply and HBC output voltage
measurement (by SNSOUT). Place this winding on the secondary (output) side to
ensure good coupling.
•
When mains insulation is included in the HBC transformer, it can impact the
construction of the auxiliary winding. Triple insulated wire is needed when the
auxiliary winding is placed on the mains-insulated area of the transformer
construction.
Fig 6.
Block diagram: SUPIC and SUPREG start-up with SUPHV and auxiliary supply
001aal018
SuplcChargeLow = 1.1 mA
SuplcCharge = 5.1 mA
SuplcCharge = off
HV START-UP SOURCE
CONTROL
0.65 V
10.9 V
5.5 mA
SUPIC
SUPHV
SUPREG
SupReg
EnableSupReg
V
AUXILIARY
reduced
current
SuplcShort
startlevel Hv = 22 V
startlevel Lv = 17 V
stoplevel = 15 V
SupRegUvStart
startlevel = 10.7 V
SupRegUvStop
stoplevel = 10.3 V
SupHvPresent
CSUPREG