NGC-40-IO

Control and Monitoring Modules for use with the 

nVent RAYCHEM NGC-40 System Installation Instructions

A

DESCRIPTION

The nVent RAYCHEM NGC-40-IO provides up to four additional 

RTD inputs. These additional RTD inputs can be assigned to 

any NGC-40-HTC/HTC3. The NGC-40-IO also has one digital 

input and one alarm relay.

TOOLS REQUIRED

•  Small flat-blade screwdriver

ADDITIONAL MATERIALS

•  Power supply 24 Vdc @100 mA per NGC-40-IO

•  Custom built CAN cables with RJ-45 connections

•  CAN Termination Resistor

KIT CONTENTS

Item Qty  Description

NGC-40-IO module

This component is an electrical device that must be installed 

correctly to ensure proper operation and to prevent shock or fire.

For technical support, call nVent at (800) 545-6258.

WARNING:

APPROVALS AND CERTIFICATIONS

Class I, Div. 2, Groups A,B,C,D T4

Class I, Zone 2, AEx nC IIC T4 IP20

Ex nL nC IIC T4 X

–40˚C ≤ Ta ≤ +65˚C 

Conforms to: 

FM Class Number 3600 (11/98)

FM Class Number 3611 (10/99)

ANSI/UL STD. 60079-15-2009

UL STD. 61010-1

Certified to:

CAN/CSA STD. C22.2 No. 213-M1987 (R2004)

CAN/CSA STD. C22.2 No. 61010-1:2004

EN 61010-1 (2001)

CAN/CSA STD. E60079-15:02 (R2006)

Hazardous Locations

3128486

Содержание RAYCHEM NGC-40-IO

Страница 1: ...nnections CAN Termination Resistor KIT CONTENTS Item Qty Description A 1 NGC 40 IO module This component is an electrical device that must be installed correctly to ensure proper operation and to prev...

Страница 2: ...relay voltage free Relay contact rated 250 V 3 A 50 60 Hz EC and 277 V 3 A 50 60 Hz cCSAus Output is user programmable to flash N0 and NC contacts available DIGITAL INPUT Multi purpose input Multi pu...

Страница 3: ...module Off No power Green OK Normal Yellow Configuration mode Red Internal fault NETWORK Indicates CAN network activity Off No link detected Green Link OK receive data packets Yellow Transmit data pac...

Страница 4: ...block Field terminal block 13 13 14 14 15 15 16 16 Filed terminal block Filed terminal block TS2 TS2 TS1 TS1 21 21 22 22 23 23 24 24 Field terminal block Field terminal block TS4 TS4 TS3 TS3 17 T S CO...

Страница 5: ...t 7 7 8 8 Terminal block Terminal block Earth grounding bar located at the I O module Earth grounding bar located at the I O module From user input From user input Digital Input Digital Input North Am...

Страница 6: ...ations for the NGC 40 IO assembly in the electrical panel The NGC 40 IO should be located in the rear of the panel The NGC 40 IO assembly is an electronic unit and must not be located where it will be...

Страница 7: ...n Module CAN 24 Vdc Primary Supply 24 Vdc Primary Supply 24 Vdc Power supply shall have a means for disconnect from line voltage Power supply shall have a means for disconnect from line voltage Redund...

Страница 8: ...ptional redundant supply CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc IN IN OUT CAN 24 Vdc HTC HTC3 or I O Module 40 IN IN OUT OUT CAN 24 Vdc HTC...

Отзывы: