background image

Cold
water in

HWAT water
heater tag

Mixing
valve

Tempered
water out

Hot water out

Hot water in

Water
heater

© 2

014

 nV

ent

 LL

C

WW

W.n

Ven

t.CO

M

PN P

000001655     H59088     0

2/1

4

For                       H

WA

T Systems install this tag on 

the hot water heater or temper

atur

e contr

ol v

alve 

ser

vicing the hot water systems.

ATTEN

TION

150°F

MA

X.

DO NO

T heat water abo

ve 150°F

. Temper

atur

es 

abo

ve 150°F

 will permanently r

educe the power 

output of the HW

AT heating cable used on this hot 

water system.

Ground wire

Red wire nuts

(Item H)

Gray wire nut

(Item I)

•  Apply warning label 

(Item G) to junction 

box cover.

•  Use red wire nuts 

(Item H) to connect 

the supply with the 

heating cable bus 

wires.

•  Use gray wire nut 

(Item I) to connect 

the ground braid to 

the supply ground.

•  Attach HWAT water heater tag 

(Item A) to either the water 

heater or temperature control 

valve servicing the hot water 

systems, using the plastic cable 

tie (Item N).

1

2

3

4

5

6

7

8

9

0

nVent.com  |  5

17

18

19

Содержание RAYCHEM HWT-P

Страница 1: ... ic in g th e h o t w at er sy st em s A T T E N T I O N 1 5 0 F M A X D O N O T h e a t w a te r a b o v e 1 5 0 F T e m p e ra tu re s a b o v e 1 5 0 F w il l p e rm a n e n tl y re d u c e th e p o w e r o u tp u t o f th e H W A T h e a ti n g c a b le u s e d o n th is h o t w a te r s y s te m HWT P HWAT Power Connection Kit with End Seal Installation Instructions This component is an elect...

Страница 2: ...asher and use black washer Item M instead Slide nut washer and grommet over the cable as shown Bevel on the washer should face into the nut Lightly score completely around and then down outer jacket Bend heating cable to break jacket at score then peel off outer jacket Power Connection Installation Carefully slide screwdriver underneath the braid and poke tip of screwdriver up through 2 3 bundles ...

Страница 3: ...own inner jacket Bend heating cable to break jacket at score then peel off inner jacket Slide heat shrinkable tubes Item E over the bus wires Starting from the center of the tube move the heat source continuously from side to side Slide heat shrinkable tube Item J over the stripped portion of the cable until tube butts up against the outer jacket To prevent the shrink tube from moving slightly spr...

Страница 4: ...l hot pinch with pliers between bus wires to seal hold for 10 seconds Starting at center of tube move heat source continuously from side to side 1 1 2 Slide grommet until end is 1 1 2 from end of outer jacket Bring cable into junction box Hand tighten nut With channel lock pliers tighten nut but do not exceed more than one 1 turn 1 2 3 4 5 6 7 8 9 0 CAUTION Health Hazard Consult included material ...

Страница 5: ...p e r a t u r e s a b o v e 1 5 0 F w il l p e r m a n e n t ly r e d u c e t h e p o w e r o u t p u t o f t h e H W A T h e a t in g c a b le u s e d o n t h is h o t w a t e r s y s t e m Ground wire Red wire nuts Item H Gray wire nut Item I Apply warning label Item G to junction box cover Use red wire nuts Item H to connect the supply with the heating cable bus wires Use gray wire nut Item I t...

Страница 6: ...moved from the heating cable 1 2 3 4 5 6 0 North America Tel 1 800 545 6258 Fax 1 800 527 5703 thermal info nvent com Europe Middle East Africa Tel 32 16 213 511 Fax 32 16 213 604 thermal info nvent com Asia Pacific Tel 86 21 2412 1688 Fax 86 21 5426 2917 cn thermal info nvent com Latin America Tel 1 713 868 4800 Fax 1 713 868 2333 thermal info nvent com 2019 nVent All nVent marks and logos are ow...

Отзывы: