14 | nVent.com
During the quick start the ESC button can be used to go back to a
previous menu. On startup the display will show the following text:
Press a key to start, and the following
menus appear:
3.1.1 Language
With the up/down arrow keys you can choose between 5 languages,
English, German, French, Danish, Italian and Czech. Press Enter to
confirm your choice.
3.1.2 Year/ Month/ Day /Hour/ Minutes
Select the year with the up/down arrow keys and press Enter to confirm.
Then select and enter the Month, Day, Hour and Minutes.
3.1.3 Cable type
Use the up/down arrow keys to select the HWAT-R (Red), HWAT-M
(Orange) or HWAT-L (yellow) cable. Select the type of cable used in your
installation. Press Enter to confirm your choice.
3.1.4 Cable length
The minimum cable length is 1 m. The maximum cable length depends
on cable type and circuit breaker capacity (See installation). Use the up/
down arrow keys to select from 1 to the maximum length (see page 10
for max. length).
Press Enter to confirm your choice.
3.1.5 Ambient temperature
The ambient temperature is the temperature inside the room where the
heating cable is installed. Use the up/down arrow keys to select from
0°C to 25°C. Press Enter to confirm.
3.1.6 Country
Select a country in this menu. This is used to set the default values
for pipe diameter and insulation thickness. For more information see
Appendix 5.1, page 23.
3.1.7 Maintain temperature
The maintain temperature is the water temperature that you set for
normal use. The temperature can be selected using the up/down arrow
keys. The minimum temperature is 37°C or the economy temperature,
whichever is higher. The maximum temperature depends on cable type,
pipe thickness, insulation thickness and ambient temperature
(see Fig. 3, page 11). The programmed maintain temperature can be
displayed by pushing the escape key once the system is in operation.
3.1.8 Economy temperature
The economy temperature is the water temperature for periods during
which hot water is not usually tapped (at night) or when lots of hot water
is tapped (peak period). The temperature can be selected using the
Quick install
Any key to start