304 Challenger
Series |
9
Application
• Duty cycle will vary depending on several factors, such as altitude,
RPM & ambient temperature�
304 Challenger
Model-Specific
Information
Pump Specifications
Air Flow @ Free Air ........................................ 210 CFM
Maximum Intermittent Vacuum................... 27-1/2” Hg
Maximum Intermittent Pressure ................. 20 psi
Operating Speed .......................................... 1000 - 1400 RPM
Porting Size ................................................... 2” (optional 1-1/2”)
Shaft Size (1/4” Key) ................................... 1-1/4”
Approximate Weight ..................................... 179 lbs
System Requirements
Shutoffs
• We recommend a primary shut-off, secondary shut-off, and an oil
catch muffler be installed on the system.
Hose
• Use 2” or larger hose to plumb your system� We recommend you
use a hose that can withstand high temperatures such as hot
tar-asphalt hose�
Pressure and Vacuum Relief Valves
• Properly adjusted pressure relief and vacuum relief valves should
also be incorporated in the system between the secondary shutoff
and the pump�
• The relief valves should be set to where the pump operates at a
maximum temperature of 375 degrees Fahrenheit�
www.fraserwoods.ca