NUVE EN 032 Скачать руководство пользователя страница 7

 

3.

 

PRECAUTIONS AND LIMITATIONS ON USE  

The user shall pay attention to the following: 

 

Do not operate the instrument for purposes other than its main purpose. 

 

The  instrument  should  only  be  used  by  authorized  and  trained  stuff  after  the  instruction 
manual has  been  read  carefully.  Only  authorized  technical  stuff  can  handle the product  in 
case of a failure. 

 

Correctly grounded power supply should be used. 

 

Only original spare parts and original accessories supplied by Nüve should be used. 

 

There should not be any material that can damage to the device in the chamber. 

 

In  necessary  cases,  the  ventilation  hole  should  be  opened  to  discharge  the  gases  and  the 
vapors occurring during heating. 

 

The set temperature should not destroy the structure of the samples. 

 

Liquids are not heated in sealed containers. 

 

The boiling points of the samples should be higher than the set temperature. 

 

Liquids which may expand during heating should not overflow from their containers. 

 

The  safety  thermostat  should  be  adjusted  to  the  temperatures  higher  than  the  set 
temperature. 

 

Check that the vapors and gases generated during the operation are not harmful to human 
health and flammable or explosive. 

4.

 

SYMBOLS 

 

Symbol in the operating instructions: 

Attention, general hazard area. 

This  symbol  refers  to  safety  relevant  warnings  and  indicates  possibly  dangerous 
situations.  The  non-adherence  to  these  warnings  can  lead  to  material  damage  and 
injury to personal. 

 

Symbol in the operating instructions: 

This symbol refers to important circumstances. 

Labels on the device: 

 

 

 

 

 

 

 

 

EN 032 Fuses 

 

EN 055 Fuses 

 

EN 120 Fuses 

 

Hot 

Surface 

Topraklı 

Priz 

(2x1,5 A) 

(2 x 2 A) 

(2 x 3 A) 

 

Содержание EN 032

Страница 1: ...N VE SANAY MALZEMELER MALAT VE T CARET A EN 032 EN 055 EN 120 INCUBATORS INSTRUCTION MANUAL Z14 K25 230 Rev No 03 Rev Date 01 2016...

Страница 2: ...e damaged instrument 4 do not operate the instrument with a damaged cable 5 do not move the instrument during operation In case of a problem contact your N ve agent for an authorized service or mainte...

Страница 3: ...nditions use of the product in non standard environmental conditions including but not limited to failure to meet requirements of ambient temperature lubrication humidity or magnetic field influences...

Страница 4: ...UNPACKING 8 5 4 MAINS SUPPLY 8 5 5 POSITIONING 8 5 6 GENERAL PRESENTATION 9 5 7 CONTROL PANEL 10 5 8 PRIOR TO OPERATION 10 6 OPERATING PRINCIPLES 11 6 2 COMPLETION OF THE WORK 12 7 PERIODIC MAINTENANC...

Страница 5: ...natural air circulation Stable and homogeneous temperature in the useful volume is provided by means of the forced air circulation through the stainless steel heaters placed onto the three outer surfa...

Страница 6: ...ard maximum pcs 2 6 2 7 2 10 Power Consumption 300 W 350 W 400 W Power Supply 230 V 50 60 Hz Internal Material Stainless Steel External Material Epoxy polyester painted steel Internal Dimensions W x D...

Страница 7: ...not destroy the structure of the samples Liquids are not heated in sealed containers The boiling points of the samples should be higher than the set temperature Liquids which may expand during heatin...

Страница 8: ...h the instrument please check them 1 ea user s manual and warranty 1 ea electrical connection cable 2 ea shelves 4 ea shelf carriers 5 4 MAINS SUPPLY The instrument requires 230V 50 60 Hz Please make...

Страница 9: ...pace between the equipment and wall 5 6 GENERAL PRESENTATION Figure 1 VENTILATION ADJUSTMENT BUTTON DISPLAY AND CONTROL PANEL DOOR HANDLE PLASTIC PADS ON OFF SWITCH FUSE HOLDER AND SUPPLY INLET VENTIL...

Страница 10: ...Temperature Value Increase and Decrease Keys These keys are used to increase or decrease the values on the temperature display 7 Time Set Key This key is pushed to set the time 1 minute 99 9 hours an...

Страница 11: ...key t n will appear on the temperature display Set the time value by pushing the value increase and decrease keys on the time adjustment side 1 minute to 99 9 hours Hold Push the time set key again t...

Страница 12: ...maintenance 7 2 CLEANING Clean the incubator and at room temperature after disconnecting the power cable Clean the incubator with a wet cloth to remove dirt and dust Use liquid detergent to remove tou...

Страница 13: ...properly The installation of the plug is not defective The mains supply is present If the incubator does not heat check the followings The program is started The safety thermostat value is adjusted hi...

Страница 14: ...14 10 ELECTRICAL CIRCUIT DIAGRAM 10 1 ELECTRICAL CIRCUIT DIAGRAM FOR EN 032 10 2 ELECTRICAL CIRCUIT DIAGRAM FOR EN 055 AND EN 120 HEATERS EN 055 2 x 700 W EN 120 2 x 800 W...

Отзывы: