Voyager IV
Nitrox System
Nuvair www.nuvair.com
Page
20
HP
Compressor
Oil Pressure
13.4 Check Compressor Lubricant Levels
Check lubricant levels before starting fill operations and add lubricant as required. Use only the
lubricants specified.
*To read LP oil level, turn the LP Compressor knob to Start position, then
immediately to the Off position. This will cycle the LP Compressor, distributing oil throughout the
system so an accurate reading may be made.
Do not allow Nitrox to be discharged into the air storage system. Nitrox
introduced into the air storage system could cause a diver to suffer from oxygen
poisoning at depth. Oxygen poisoning is extremely dangerous and can lead to
death by drowning.
Do not allow air to be discharged into the Nitrox storage system. Air introduced into the Nitrox
storage system could cause a diver to suffer decompression sickness if the Nitrox mixture is
not analyzed properly and is used underwater under the assumption it is a different mix.
13.5 Control Panel Controls
Compressor
Lubricant
Level Sight
Gauges
Check Oil
Level*
Cabinet
Temperature
Gauge
Feed Air
Pressure
Gauge
LP
Compressor
Oil
Temperature
Heater
Temperature
Gauge
Fill
Pressure
Gauge
On/Off
Switches
LP Feed Air
Regulator
Adjustment
Knob
Stage
Pressure
Gauges
O
2
Analyzers