2.0 System Description 

 
The Pro HE

TM

 Helium Analyzer measures helium (He) levels in gases in the range of 0 to 100% 

of volume with a.1% resolution.  It can be used to measure the He content in all breathing gas 
mixes.  The Analyzer is designed to verify helium concentration in stored gas cylinders as well 
as to monitor continuous flow of gas from a compressor. The Analyzer is a moisture and impact 
resistant unit compatible with outdoor and marine environments. 

 

Helium is a colorless, odorless, tasteless gas that will not support life. 
Exposure to Helium can lead to unconsciousness and death. 

 
The Analyzer is battery powered or 110/230V and 
includes an internally mounted sensor with audible & 
visual alarm.  The water-resistant case includes a 
digital display and controls that are environmentally 
sealed 
 
The Analyzer uses a Flow Adapter Cap and Flexible 
tubing to deliver sample gas to the Sensor.  
Pressurized gases must be regulated to avoid damage 
to the analyzer.  Use of this Analyzer in a hyperbaric 
chamber will void the owner’s warranty. 
 
The Analyzer is self calibrating and ready for use after 
powering on. Certified calibration gas should be used 
periodically to confirm the accuracy of the analyzer 
sensor and electronics are working properly.  
 
 

 

This analyzer is designed for use at atmospheric pressures only. It is not designed for 
exposures in a hyperbaric chamber. Use of this analyzer in a hyperbaric chamber will 
result in incorrect readings and may damage the unit. 

 

Although the Analyzer is a rugged instrument, careless handling or abuse may result in 
damage to the Analyzer resulting in inaccurate gas analysis. Inaccurate gas analysis can 
lead to serious personal injury or death. 

 

 

Extreme Helium exposure levels directed at the Analyzer sensor may damage the sensor. 

 

 

 

Flow 

Adapter Cap 
Over Sensor 

Face

 

Water-

Resistant 

Case

 

Содержание PRO HE

Страница 1: ...Operation Manual Pro He AlarmTM Helium Analyzer Rev 07 16...

Страница 2: ...his Operation Manual contains important safety information and should always be available to those personnel operating this equipment Read understand and retain all instructions before operating this...

Страница 3: ...2Programming Procedures 4 3Alarm Setting 4 4 Full Scale Value Setting 4 5 Auto Off Delay Time Setting 5 0Threshold Alarms 6 0 Powering Off 7 0 Factory Reset 8 0 Maintenance 8 1Analyzer Care 8 2Battery...

Страница 4: ...rmation introduced by the following signal words Indicates an imminently hazardous situation which if not avoided will result in serious personal injury or death Indicates a potentially hazardous situ...

Страница 5: ...entally sealed The Analyzer uses a Flow Adapter Cap and Flexible tubing to deliver sample gas to the Sensor Pressurized gases must be regulated to avoid damage to the analyzer Use of this Analyzer in...

Страница 6: ...He TM Alarm Helium Analyzer NUVAIR Page 6 www nuvair com 2 0 Description Model 9627 Model 9628 Model He Model He with rechargeable Lithium Polymer battery Only use Nuvair supplied charger for this bat...

Страница 7: ...uum must be avoided 2 5 Batteries The 9627 29628 use one 9 volt battery for power The battery is located inside the Analyzer and is user replaceable These models can be supplied with a 110 230V power...

Страница 8: ...correct readings may expose the user to high levels of carbon Dioxide resulting in personal injury or death Checking Calibration or use of the Analyzer with a low battery may result in inaccurate read...

Страница 9: ...us twice before returning the home screen Gas even under moderate pressures can cause extreme bodily harm Never allow any gas stream to be directed at any part of your body Never expose the sensor to...

Страница 10: ...s must contain a known amount of Helium for calibration test to succeed Step 1 Attach Flexible Tubing to Gas Sample Flow of 0 5 to 1 L min Step 2 Verify that Gas is Flowing Out Holes in Flow Adapter C...

Страница 11: ...2 High alarm point expressed in ppm of Helium concentration o FSC Value expressed in ppm of Helium concentration corresponding to the current output full scale value 20mA 4mA always correspond to 1999...

Страница 12: ...as the Alarm settings 1 Press the Prog button for more than two seconds and then release the button On the display will appear Pr for two seconds then AL 1 will appear Press the On Off button to cycl...

Страница 13: ...ll display OFF and then go blank 7 0 Factory Reset In case it is necessary to reset the Pro He Analyzer to the factory settings or the displayed Helium Percentage does not correlate with the content o...

Страница 14: ...act may result in incorrect readings Incorrect gas analysis may result in personal injury or death Protect the analyzer from exposure to hyperbaric environments Exposure to hyperbaric environments may...

Страница 15: ...replace the batteries in the Analyzer He Model Remove four nuts and pull out aluminum plate Under this plate is the Lithium Polymer battery Contact Nuvair for a replacement battery Step 1 Remove Screw...

Страница 16: ...se any other helium sensor brands for replacement 9 0Spares 9 1 Calibration Equipment Calibration check requires certified He calibration gas to be delivered at a specific flow rate and pressure A var...

Страница 17: ...ff Bad connection Low Battery Switch on Check display battery connection Change the battery Reading erratic Pressure on sensor Radio transmission Sensor old or faulty Condensation on sensor Check flow...

Страница 18: ...utput uses a special Mini Jack plug that can be purchased separately from Nuvair Insert the plug into the output jack Connections diagram below for additional wiring The plug should be connected or di...

Страница 19: ...n the sensing surface Note All specifications are at ambient sea level 77 F 25 C and subject to change without notice Charger Specifications for Lithium Polymer rechargeable battery Models Features 11...

Страница 20: ...ill begin with the date of manufacture by NUVAIR Maintenance Items Any materials which are consumed or otherwise rendered not warrantable due to processes applied to them are considered expendable and...

Страница 21: ...Pro He TM Alarm Helium Analyzer NUVAIR Page 21 www nuvair com Notes...

Страница 22: ...Notes...

Страница 23: ...Notes...

Страница 24: ...Nuvair Phone 805 815 4044 Fax 805 486 0900 1600 Beacon Place Oxnard CA 93033 USA Email info nuvair com Web www nuvair com Revision 07 16...

Отзывы: