background image

Pro He

TM

 Alarm Helium Analyzer 

 

NUVAIR 

Page 

20 

www.nuvair.com

 

 

NUVAIR Pro He

TM

 Warranty 

 

NUVAIR extends a limited warranty, which warrants the Pro He

TM

 to be free from defects in materials 

and workmanship under normal use and service for a limited period.  The Pro He is warranted according 
to the pro-rated terms as set forth below.  This warranty is not transferable. 
 
NUVAIR will, at it’s discretion and according to the terms as set forth within, replace or repair any 
materials which fail under normal use and service and do not exhibit any signs of improper maintenance, 
misuse, accident, alteration, weather damage, tampering, or use for any other than the intended purpose.  
Determination of failure is the responsibility of NUVAIR, which will work together with the customer to 
adequately address warranty issues.  When any materials are repaired or replaced during the warranty 
period, they are warranted only for the remainder of the original warranty period.  This warranty shall be 
void and NUVAIR shall have no responsibility to repair or replace damaged materials resulting directly or 
indirectly from the use of repair or replacement parts not approved by NUVAIR. 
 
Terms: 
NUVAIR warrants the Pro He to be free from defects in material and workmanship for a period of twelve 
(12) months from date of purchase.  The warranty covers parts and labor. 
 
A warranty registration card, supplied with system documentation, must be filled out and submitted to 
NUVAIR for the warranty to be registered.  If the warranty registration card is not received within ten (10) 
days of purchase, the warranty will begin with the date of manufacture by NUVAIR. 
 
Maintenance Items: 
Any materials which are consumed, or otherwise rendered not warrantable due to processes applied to 
them, are considered expendable and are not covered under the terms of this policy.  This includes 
batteries. 
 
Return Policy: 
Application for warranty service can be made by contacting NUVAIR during regular business hours and 
requesting a Return Material Authorization number.  Materials that are found to be defective must be 
shipped, freight pre-paid, to the NUVAIR office in Oxnard, California.  Upon inspection and determination 
of failure, NUVAIR shall exercise its options under the terms of this policy.  Warranty serviced materials 
will be returned to the customer via NUVAIR’s preferred shipping method, at NUVAIR’s expense.  Any 
expedited return shipping arrangements to be made at customer’s expense must be specified in 
advance. 
 
Limitation of Warranty and Liability: 
Repair, replacement or refund in the manner and within the time provided shall constitute NUVAIR’S sole 
liability and the Purchaser’s exclusive remedy resulting from any nonconformity or defect. NUVAIR shall 
not in any event be liable for any damages, whether based on contract, warranty, negligence, strict 
liability or otherwise, including without limitation any consequential, incidental or special damages, arising 
with respect to the equipment or its failure to operate, even if NUVAIR has been advised of the possibility 
thereof.  NUVAIR makes no other warranty or representation of any kind, except that of title, and all other 
warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, 
are hereby expressly disclaimed. No salesman or other representative of NUVAIR has authority to make 
any warranties. 

 
 

 

Содержание PRO HE

Страница 1: ...Operation Manual Pro He AlarmTM Helium Analyzer Rev 07 16...

Страница 2: ...his Operation Manual contains important safety information and should always be available to those personnel operating this equipment Read understand and retain all instructions before operating this...

Страница 3: ...2Programming Procedures 4 3Alarm Setting 4 4 Full Scale Value Setting 4 5 Auto Off Delay Time Setting 5 0Threshold Alarms 6 0 Powering Off 7 0 Factory Reset 8 0 Maintenance 8 1Analyzer Care 8 2Battery...

Страница 4: ...rmation introduced by the following signal words Indicates an imminently hazardous situation which if not avoided will result in serious personal injury or death Indicates a potentially hazardous situ...

Страница 5: ...entally sealed The Analyzer uses a Flow Adapter Cap and Flexible tubing to deliver sample gas to the Sensor Pressurized gases must be regulated to avoid damage to the analyzer Use of this Analyzer in...

Страница 6: ...He TM Alarm Helium Analyzer NUVAIR Page 6 www nuvair com 2 0 Description Model 9627 Model 9628 Model He Model He with rechargeable Lithium Polymer battery Only use Nuvair supplied charger for this bat...

Страница 7: ...uum must be avoided 2 5 Batteries The 9627 29628 use one 9 volt battery for power The battery is located inside the Analyzer and is user replaceable These models can be supplied with a 110 230V power...

Страница 8: ...correct readings may expose the user to high levels of carbon Dioxide resulting in personal injury or death Checking Calibration or use of the Analyzer with a low battery may result in inaccurate read...

Страница 9: ...us twice before returning the home screen Gas even under moderate pressures can cause extreme bodily harm Never allow any gas stream to be directed at any part of your body Never expose the sensor to...

Страница 10: ...s must contain a known amount of Helium for calibration test to succeed Step 1 Attach Flexible Tubing to Gas Sample Flow of 0 5 to 1 L min Step 2 Verify that Gas is Flowing Out Holes in Flow Adapter C...

Страница 11: ...2 High alarm point expressed in ppm of Helium concentration o FSC Value expressed in ppm of Helium concentration corresponding to the current output full scale value 20mA 4mA always correspond to 1999...

Страница 12: ...as the Alarm settings 1 Press the Prog button for more than two seconds and then release the button On the display will appear Pr for two seconds then AL 1 will appear Press the On Off button to cycl...

Страница 13: ...ll display OFF and then go blank 7 0 Factory Reset In case it is necessary to reset the Pro He Analyzer to the factory settings or the displayed Helium Percentage does not correlate with the content o...

Страница 14: ...act may result in incorrect readings Incorrect gas analysis may result in personal injury or death Protect the analyzer from exposure to hyperbaric environments Exposure to hyperbaric environments may...

Страница 15: ...replace the batteries in the Analyzer He Model Remove four nuts and pull out aluminum plate Under this plate is the Lithium Polymer battery Contact Nuvair for a replacement battery Step 1 Remove Screw...

Страница 16: ...se any other helium sensor brands for replacement 9 0Spares 9 1 Calibration Equipment Calibration check requires certified He calibration gas to be delivered at a specific flow rate and pressure A var...

Страница 17: ...ff Bad connection Low Battery Switch on Check display battery connection Change the battery Reading erratic Pressure on sensor Radio transmission Sensor old or faulty Condensation on sensor Check flow...

Страница 18: ...utput uses a special Mini Jack plug that can be purchased separately from Nuvair Insert the plug into the output jack Connections diagram below for additional wiring The plug should be connected or di...

Страница 19: ...n the sensing surface Note All specifications are at ambient sea level 77 F 25 C and subject to change without notice Charger Specifications for Lithium Polymer rechargeable battery Models Features 11...

Страница 20: ...ill begin with the date of manufacture by NUVAIR Maintenance Items Any materials which are consumed or otherwise rendered not warrantable due to processes applied to them are considered expendable and...

Страница 21: ...Pro He TM Alarm Helium Analyzer NUVAIR Page 21 www nuvair com Notes...

Страница 22: ...Notes...

Страница 23: ...Notes...

Страница 24: ...Nuvair Phone 805 815 4044 Fax 805 486 0900 1600 Beacon Place Oxnard CA 93033 USA Email info nuvair com Web www nuvair com Revision 07 16...

Отзывы: