background image

 

 

 

NSS Series 

Nuvair 

 

Page 26 

www.Nuvair.com 

 

15.0  Nuvair Fill Containment Station System Warranty

 

 

Nuvair extends a limited warranty, which warrants the fill containment station system to be free from defects in 

materials and workmanship under normal use and service for a limited period.  All other Original Equipment 

Manufacturer (OEM) components used in the system are warranted only to the extent of the OEM’s warranty to 

Nuvair.  Nuvair makes no warranty with respect to these OEM components, and only warrants the 

workmanship that Nuvair has employed in the installation or use of any OEM component.  This warranty is not 

transferable. 

 

Nuvair will, at its discretion and according to the terms as set forth within, replace or repair any materials which 

fail under normal use and service and do not exhibit any signs of improper maintenance, misuse, accident, 

alteration, weather damage, tampering, or use for any other than the intended purpose.  Determination of 

failure is the responsibility of Nuvair, which will work together with the customer to adequately address 

warranty issues.  When any materials are repaired or replaced during the warranty period, they are warranted 

only for the remainder of the original warranty period.  This warranty shall be void and Nuvair shall have no 

responsibility to repair or replace damaged materials resulting directly or indirectly from the use of repair or 

replacement parts not approved by Nuvair. 

 

Maintenance Items 

Any materials which are consumed, or otherwise rendered not warrantable due to processes applied to them, 

are considered expendable and are not covered under the terms of this policy.  This includes maintenance and 

consumable items listed as part of a suggested maintenance program included with system documentation. 

 

Return Policy 

Application for warranty service can be made by contacting Nuvair during regular business hours and 

requesting a Return Material Authorization (RMA) number.  Materials that are found to be defective must be 

shipped, freight prepaid, to the Nuvair office in Oxnard, California USA.  Upon inspection and determination of 

failure, Nuvair shall exercise its options under the terms of this policy.  Warranty serviced materials will be 

returned to the customer via Nuvair’s preferred shipping method, at Nuvair’s expense. Any expedited return 

shipping arrangements to be made at customer’s expense must be specified in advance. 

 

Limitation of Warranty and Liability 

Repair, replacement, or refund in the manner and within the time provided shall constitute Nuvair’s sole liability 

and the purchaser’s exclusive remedy resulting from any nonconformity or defect. Nuvair shall not in any event 

be liable for any damages, whether based on contract, warranty, negligence, strict liability or otherwise, 

including without limitation any consequential, incidental, or special damages, arising with respect to the 

equipment or its failure to operate, even if Nuvair has been advised of the possibility thereof.  Nuvair makes no 

other warranty or representation of any kind, except that of title, and all other warranties, express or implied, 

including warranties of merchantability and fitness for a particular purpose, are hereby expressly disclaimed. 

No salesman or other representative of Nuvair has authority to make any warranties. 

Содержание NSS Series

Страница 1: ...Operation Manual Fill Containment Station SKU NSS 2P OCA as shown...

Страница 2: ...n contained within Nuvair however retains the right to modify its contents without notice Under Nuvair s system of continuous improvement certain components may be updated or changed as higher quality...

Страница 3: ...ation 12 8 0 Checks for the Start of Each Working Day 12 8 1 Check Refill Hoses 12 8 2 Storing Technical Documentation 12 9 0 Fill Containment Station Operation 13 10 0 Maintenance 19 10 1 Foreword 19...

Страница 4: ...t hazard related 1 2 System Description The Nuvair NSS Fill Containment Station Series is designed for use while filling high pressure gas cylinders DIN yoke or SCBA The all steel construction of the...

Страница 5: ...essential component of the supplied fill containment station These regulations instructions are intended for an operator who has already been trained to use this type of fill containment station The...

Страница 6: ...essure Use the fill containment station in areas free from dust risk of explosion corrosion and fire Improper use could have serious consequences for the user Do not disconnect the hose from the fitti...

Страница 7: ...the fill containment station is pressurized Do not empty storage tanks completely not even for long term storage as this practice allows damp air to get in and eventually corrode the tank It is forbid...

Страница 8: ...arts are left on the fill containment station 9 Do not use flammable solvents for cleaning 10 Exercise cleanliness during maintenance and when making repairs Keep dirt away from parts by covering part...

Страница 9: ...nment Station Layout Storage Bank 1 Gauge Panel Valve Storage Bank 2 Gauge Panel Valve Pneumatic Door Open Close Switch Fill Station 1 Gauge Valve Regulated Fill Pressure Gauge Fill Station 2 Gauge Va...

Страница 10: ...vair Page 10 www Nuvair com WARNING Turn off compressor input valve if transferring gas mixtures of more than 21 oxygen content between Storage Bank 1 and Storage Bank 2 Compressor Input Valve OCA Fil...

Страница 11: ...tainment station carefully every day it is used as per the checklist given in this manual 5 0 Safety Information Labels Location Description Safety information labels are affixed to various parts of t...

Страница 12: ...necessary or contact Nuvair 8 1 Check Refill Hoses Inspect the refill hoses and make sure there are no cuts holes abrasions leaks etc If necessary replace with new hoses 8 2 Storing Technical Document...

Страница 13: ...llow procedures described below and as illustrated in Figure 4 Check that cylinders to be refilled are in good condition o Cylinders must be inspected as required by local law and have evidence stampe...

Страница 14: ...damage caused by moisture intrusion Step 2 Turn HP to HP regulator counterclockwise decrease Step 3 Open front door by turning door switch Door opens automatically Step 4 Check cylinder for proper rat...

Страница 15: ...vair Page 15 www Nuvair com Step 6 Connect fill whip to cylinder Step 7 Close fill whip bleed drain Step 8 Open cylinder valve Step 9 Close door Step 10 Open fill station valve Step 11 Open tank fill...

Страница 16: ...ncrease regulator pressure to desired fill pressure Step 13 When cylinder is full close tank fill valve Step 14 Open fill station door Step 15 Close cylinder valve Step 16 Open fill whip bleed valve t...

Страница 17: ...s Nuvair Page 17 www Nuvair com Step 20 Close fill station door Step 21 Turn fill supply off Step 18 Remove cylinder from compartment Step 19 Repeat steps 4 to 18 to fill additional cylinders or go to...

Страница 18: ...of fill whip fitting See image below for additional information Bleed pressure from fill whip valve before removing fitting from cylinder SKU GO18 Bleed pressure from fill whip valve before removing f...

Страница 19: ...cording to the most advanced technological criteria requires only minimum preventive and routine maintenance The residual pressure present in the fill containment station and all lines must be release...

Страница 20: ...paper mounted inside the cartridge element turns white or a color other than blue The fill containment station comes standard with one 1 drying filter SKU X96677 and one 1 breathing air filter SKU X9...

Страница 21: ...from the wall socket WARNING Be sure that all pressure has been relieved from the system prior to opening any filtration canister Failure to vent pressure from the system prior to opening the caniste...

Страница 22: ...are correctly connected and in good condition Check also that the valves on any unused hoses are closed properly to prevent the dangers associated with hose whipping To change the tank refill hoses p...

Страница 23: ...t assistance and register completed scheduled maintenance work Start up and maintenance checks tasks once completed by our qualified technician are registered in this maintenance chapter by way of an...

Страница 24: ...NSS Series Nuvair Page 24 www Nuvair com 13 0 Service Log Date Technician Name Service Performed...

Страница 25: ...mg m 5 mg m Odor None None Notes Dew point of supply air must be 10o F 6o C colder than coldest ambient air expected Supply air delivered to the membrane system must contain 0 003 PPM oil vapor 14 2...

Страница 26: ...plied to them are considered expendable and are not covered under the terms of this policy This includes maintenance and consumable items listed as part of a suggested maintenance program included wit...

Страница 27: ...uvair This card is to establish registration for any necessary warranty work and as a means of communication that allows Nuvair to contact the user regarding this product The user must notify Nuvair o...

Страница 28: ...Series Nuvair Page 28 www Nuvair com Nuvair Phone 1 805 815 4044 Fax 1 805 486 0900 Address 1600 Beacon Place Oxnard CA 93033 USA Email info nuvair com Website www Nuvair com Rev 08 2022 SKU NSS Seri...

Отзывы: