Make sure the minimum bending radius of the hose is no less than 250 mm (9.8 inches).
To ensure maximum working efficiency, Nuvair
has constructed the compressor with carefully selected
components and materials. The compressor is tested prior to delivery. Continued compressor efficiency over
time will also depend on proper use and maintenance as per the instructions contained in this manual.
All the components, connections and controls used in its construction have been designed and built to a high
degree of safety to resist abnormal strain or in any case a strain greater than that indicated in the manual.
Materials are of the finest quality; their introduction and storage in the company and their utilization in the
workshop are controlled constantly to prevent any damage, deterioration, or malfunction.
Before carrying out any work on the compressor each operator must have a perfect understanding of
how the compressor works, know how to use the controls, and have read the technical information
contained in this manual.
•
It is forbidden to use the compressor under conditions or for purposes other than those
indicated in this manual and Nuvair cannot be held liable for breakdowns, problems or
accidents caused by failure to observe this rule.
•
Check that the fittings provide a proper seal by wetting them with soapy water: Stop the
compressor and eliminate any leaks immediately when detected.
•
Do not attempt to repair high pressure tubes by welding them or while the compressor is
running.
•
Do not empty storage tanks completely
—not even for long term storage—as this practice allows
damp air to get in and eventually corrode the tank.
•
It is forbidden to tamper with, alter or modify, even partially, the systems and equipment
described in this instruction manual, especially as safety guards and safety symbols are
concerned.
•
It is also forbidden to carry out work in any way other than that described or to neglect the
illustrated safety tasks.
•
The safety information and the general information given in this manual are very important.
1.7
Where the Compressor May be Used
The compressor must only be used in environments having the characteristics described in the following table:
Area of Machine Use: Essential Data Table
Temperature Ambient
Minimum: +14°F (+14°C); Maximum: +104°F (+40°C)
Air Humidity
Maximum: 80%
rain
Tolerated Weather Conditions
hail
None
snow
Maximum Tilt Angle (bank)
15%
Check that the area in which the compressor is to be positioned is adequately ventilated: good air exchange
(more than one window) with no dust and no risk of explosion, corrosion, or fire.