MCH36 Silent Touch
Nuvair
Page 10
www.Nuvair.com
Maintenance and repairs must only be carried out using original spare parts and qualified technicians.
Nuvair cannot be held liable for any damages caused by failure to observe this rule. The compressor is
guaranteed as per the contractual agreements made at the time of sale. Failure to observe the
regulations and instructions for use contained in this manual shall render the warranty null and void.
1.6
Purpose of the Machine
This high-pressure compressor
has been designed and built for the purpose of producing breathing air by
drawing it from the surrounding environment. The surrounding environment air must be free from any harmful
fumes or contaminates. The air is pulled through an intake air filter, compressed, and passed through
breathing air filtration before it is stored in tanks constructed to contain air at high pressure. The compressor
can also be used for the pumping of gases:
•
Nitrogen
•
Helium
•
Nitrox mixtures up to 40%
Any other use is inappropriate. The manufacturer cannot be held liable for any personal injury or damage to
objects or the machine itself caused by improper use.
•
Use only tested, certified storage tanks: do not exceed the working pressure indicated on them.
•
Use the compressor in areas free from dust, risk of explosion, corrosion, and fire.
•
Improper use could have serious consequences for the user.
•
Do not disconnect the hose from the fittings or the clamp when under pressure.
•
Change the air purification filters regularly as described in section 13.0.
•
Drain the condensate regularly as illustrated in section 13.2: Condensate Discharge.
•
The power must be disconnected and locked out before carrying out any cleaning or maintenance
tasks.
•
Never pull a plug out by tugging the cord. Make sure the cord is not bent at a sharp angle and that it
does not rub against any sharp edges. Use of extensions is not advised.
•
Never operate the compressor when the power cord is damaged, or the power supply
covers/guards are removed.
•
All routine and unscheduled maintenance tasks must be carried out with the compressor at a
standstill, the electrical power supply disconnected or locked out and all lines are depressurized.
•
After switching off the compressor wait about 30 minutes before carrying out any maintenance
tasks to prevent burns.
•
The high-pressure flex hose that connects to external components must be in good condition,
especially in the areas near the fittings.
o
The plastic sheath that covers the pipe must not show any signs of abrasion otherwise damp
could get in, corrode the steel braid and weaken it.
o
The hose must be changed periodically (yearly) or when it shows signs of wear.
o
Failure to observe this rule could seriously endanger the users’ safety.