6.0 

System Component Identification: 

The 

Champion R15 

system is a self-contained, portable, low pressure delivery package capable of 

supplying Air for the divers use. 
 
The system utilizes a  Champion R15  low-pressure compressor that is  mounted together with 10hp 
Yanmar or Kohler Diesel Engine or 5hp WEG or Baldor electric Motor in a rigid, aluminum frame or 
on a volume tank.  The system components include: Marine Grade Frame, Compressor and motor.  
All of the component assemblies and parts are mounted to facilitate easy set-up, operation, and 
transport. 
 

Champion R15 Diesel Compressor System Components 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

  

 

 

    

 

 

 

See Yanmar Manual  

for Yanmar Operation 

R15 Oil Drain 

Champion R15 

Intake Filter 

Diesel Exhaust. 

Keep exhaust away 

from compressor air 

intakes. 

Increase height if 

necessary 

CO in Exhaust Can Kill 

(Optional) HF20-7 

Oil Vapor Removal 

No Auto Drain 

Visually Check for Moisture 

Daily 

 

(optional) HF20-1 

Coalescing Filter 

With Auto Drain 

(Optional) HF20-5 

Oil & Particulates 

With Auto Drain 

Electric 

Start 

option 

Engine Fuel 

Fill Cap 

Belt Guard 

Do Not 

Remove while in 

Operation  

Compressor 

Air Pressure 

Available Options Necessary for Using the Champion 

Compressors for Diving 

 

LP Diver Air Filtration 

Volume Tank 

High Temp Sensor for Compressor Block 

CO Analyzer- Shutdown, lights, Alarm 

Regulator 

Low Pressure Switch 

Low Oil Level Switch 

Low Pressure Switch 

 

Be sure to check with your local agency for standards 

that require options to be in place before using the 

Champion Compressors for working divers. 

 

Over Pressure 

Relief 

 

Oil Fill 

Oil Sight 

Gauge 

Содержание Champion LP

Страница 1: ...Operation Manual Nuvair Champion LP Diesel Electric rev 050112...

Страница 2: ...is Operation Manual contains important safety information and should always be available to those personnel operating this equipment Read understand and retain all instructions before operating this e...

Страница 3: ...on 12 10 0 Set Up and Assembly 12 10 1 Power Connections 12 10 2 Proper Rotation 12 11 0 Operation 13 11 1 Shutdown 13 12 0 Operation Notes 14 13 0 Maintenance 14 13 1 Routine Maintenance 14 13 2 Comp...

Страница 4: ...uals included Throughout this manual we will use certain words to call your attention to conditions practices or techniques that may directly affect your safety Pay particular attention to information...

Страница 5: ...eparates from its restraint or termination while under pressure and strikes any part of your body Use appropriate care in making and handling all gas connections Never mix the Compressor Lubricant wit...

Страница 6: ...r loose parts are left on the Compressor System 13 Do not use flammable solvents for cleaning the Air Inlet Filters or elements and other parts 14 Exercise cleanliness during maintenance and when maki...

Страница 7: ...of Air Compressor Systems Operators of Nuvair compressors should consult your local and or national government and or managing bodies to determine the regulation obligations necessary to operate a Nuv...

Страница 8: ...els handles lifting eye and fork lift slots Vibration Isolation Mounts 1 x Low pressure Two Stage Compressor Option 1 x 1 Gallon ASME LP Surge Tank with delivery ball valve Yanmar or Kohler 10 HP dies...

Страница 9: ...25HP diesel or Kohler 23 HP Gas engine with electric start or WEG or Baldor Electric Motor 15hp or20hp Air Compressor Technical Data LP Compressor 39 59 cfm 175psi Maximum Block Output Pressure 200 P...

Страница 10: ...ration R15 Oil Drain Champion R15 Intake Filter Diesel Exhaust Keep exhaust away from compressor air intakes Increase height if necessary CO in Exhaust Can Kill Optional HF20 7 Oil Vapor Removal No Au...

Страница 11: ...r Will monitor CO levels of air supply being delivered to the diver manifold These items are required to use the compressor package for Diver Breathing Air Required to be compliant with some Diving st...

Страница 12: ...ailed information about the damage 10 0 Set up and Assembly 10 1 Power Connection This package comes with a 12 volt battery for the Diesel electric start to function properly Red Is Positive Connectin...

Страница 13: ...Tank valves for Air 3 Start diesel as per instructions or electric motor 4 Turn off diver Air Valves 5 Warm for a few minutes Diesel engine 6 Adjust throttle to run position Diesel engine OSHA Regulat...

Страница 14: ...sonal injury or death If system is located in an area where there is high humidity and high heat the life of all Filtration Elements may be as little as 35 of rated operating capacity Check the compre...

Страница 15: ...on and may result in system damage This can lead to severe personal injury and death Wear eye protection gloves and skin protection when performing oil changes Although the oil is not classified as a...

Страница 16: ...ct as follows 1 Inspect Bowl for the presence of moisture A high level of moisture build up in the HF7 or HF5 Filter indicates improper operation of auto drain floats Any evidence of moisture in the H...

Страница 17: ...Air Intake Filtration Inspect and or change the air intake Filter Elements every 40 hours or once per year If the Compressor System is operated in high humidity or a dusty dirty environment Filter El...

Страница 18: ...s list Other System components and related items are listed below System Components Type Part Number Compressor Lubricant Food Grade Nuvair 455 1 Gal Other Sizes Available 9406 LP Filtration Element R...

Страница 19: ...Nuvair Champion LP NUVAIR rev 010512 Champion LP Operation Manual Page 19 16 0 Service Record Log Date Technician Name Service Performed...

Страница 20: ...ous Decomposition Products Carbon monoxide Carbon dioxide VI Health Information Eye Contact Flush eyes with water for 15 minutes Call physician if irritation develops Skin Contact Wash skin with soap...

Страница 21: ...egin with the date of shipment from NUVAIR Maintenance Items Any materials which are consumed or otherwise rendered not warrantable due to processes applied to them are considered expendable and are n...

Страница 22: ...Pro CO High Temp Combo 30 Gallon or Larger receiver tank Breathing Air Filtration 3 Stage or 4 stage Low Oil Level Switch Low Oil Pressure Switch Low Tank Pressure Switch 4 Point Lifting Eyes Enclosed...

Страница 23: ...Nuvair Champion LP NUVAIR rev 10512 Champion LP Operation Manual...

Страница 24: ...n LP NUVAIR rev 10512 Champion LP Operation Manual Nuvair 2012 All Rights Reserved Phone 1 805 815 4044 Fax 1 805 815 4196 2949 West 5th Street Oxnard CA 93030 USA Email info nuvair com Web www nuvair...

Отзывы: