background image

READ & SAVE THESE INSTRUCTIONS!

INSTALLATION INSTRUCTIONS

Timer Switches

1. The timer assembly is designed to mount in a 2-1/2" deep

single-gang box.

2. Run house power wiring (with ground) from fuse or

circuit breaker box and wiring from ventilation fan (refer
to fan motor plate for wiring instructions to motor) to
timer in outlet box and make connections as illustrated in
Figure 1.

3. Strip wires approximately 1/2" to make connections.

Connect wire to terminal screws in timer side. 

NOTE:

Use LINE-1/LOAD-1 for standard operation. LINE-
2/LOAD-2 will turn the current on at the end of
timing period.

4. Insert wired timer into wall box with “TOP” (indicated on

front cover) in proper position. Refer to Figure 2.

5. Fasten timer to wall box using (2) screws provided.
6. Fasten wall plate to timer using the (2) screws provided

with the plate. The screw must be self-tapped into the
timer body and will require a gentle inward pressure
while firmly turning the screw.

7. Position small plastic timer dial so that “OFF” is in  the

up position. Install hex nut and tighten.

8. Push knob on shaft with the tail facing down.

Timer Operating Instructions:

1. Turn knob clockwise (to the right) to desired time period.

Timer will automatically turn “OFF” at the end of period.

2. Regardless of time period desired, knob must first be

rotated past “TURN PAST” as indicated on timer dial. It
may then be turned back to a shorter time period if
desired.

FIGURE 1

FIGURE 2

MODELS: VS-62WH, VS-63WH

CAUTION: Do not supply house power until installation is
complete.
All wiring must comply with local codes and switch must
be properly grounded.

TO NUTONE UNIT

120 VAC 60 HZ

HOUSE POWER

WHITE

(NEUTRAL)

BLACK (HOT)

GROUND

TIMER

EARTH 

GROUND 

(GREEN)

WHITE

(NEUTRAL)

BLACK (HOT)

TOP

“OFF”

POSITION

Отзывы: