background image

Page 4

MODEL   QTXEN110H  

SERVICE PARTS

30042346

 

Key No.  Part No. 

Description

 1  97016466 

Housing

 2  97017187 

Duct 

Connector-6”

 3  98010102 

Wiring 

Plate

 

99170245 

Screw, #8-18 X .375 (2 req’d)

 

97017086 

Wire Panel/Harness Assembly *

 6  99020284 

Blower 

Wheel

 7  99080580 

Motor

 

99100491 

Isolator (4 req’d)

 

97017083 

Motor Plate & Control Assembly *

 

10 

99250959 

Washer #8 (4 req’d)

 

11 

99260558 

Nut, Hex Lock #8-32 (4 req’d)

 *  97017087 

Blower 

Assembly 

*

 

 

 

  (includes key nos. 6 thru 11)

 12  97016964 Grille 

Assembly 

*

 

 

 

  (includes key nos. 13 & 16)

 

13 

99140199 

Grille Spring (2 req’d)

 

14 

99111293 

Spacer (2 supplied)

 

15 

97016909 

Hanger Bar Kit

 16  99271344 Sensor 

Wire 

Harness

TAB

* Parts not listed are included with Assembly.
Order service parts by “Part No.” - not by “Key No.”

INSTALL GRILLE

6. Finish ceiling.

 

Install ceiling material. Cut out around housing.

7.  Plug in wiring.

 

Plug wiring into the proper receptacles.

8.  Attach grille to 

housing.

 

Squeeze grille springs 

and insert them into slots 

on each side of housing.

9.  Push grille against 

ceiling.

WARRANTY

NUTONE THREE YEAR LIMITED WARRANTY

NuTone warrants to the original consumer purchaser of its products that such 

products will be free from defects in materials or workmanship for a period 

of three years from the date of original purchase. THERE ARE NO OTHER 

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED 

TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 

PARTICULAR PURPOSE. During this three-year period, NuTone will, at its 

option, repair or replace, without charge, any product or part which is found 

to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP START-

ERS AND TUBES. This warranty does not cover (a) normal maintenance 

and service or (b) any products or parts which have been subject to misuse, 

negligence, accident, improper maintenance or repair (other than by NuTone), 

faulty installation or installation contrary to recommended installation instruc-

tions. The duration of an implied warranty is limited to the three-year period 

as speci

fi

 ed for the express warranty. Some states do not allow limitation on 

how long an implied warranty lasts, so the above limitation may not apply to 

you. NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S 

OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY 

UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCI-

DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF 

OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some 

states do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation may not apply to you.
This warranty gives you speci

fi

 c legal rights, and you may also have other 

rights, which vary from state to state. This warranty supersedes all prior 

warranties. To qualify for warranty service, you must (a) notify NuTone at the 

address or telephone number stated below, (b) give the model number and 

part identi

fi

 cation and (c) describe the nature of any defect in the product or 

part. At 

the time of requesting warranty service, you must present evidence 

of the original purchase date.

Broan-NuTone Canada Inc.,

 1140 Tristar Drive, Mississauga, ON L5T 1H9

(1-888-882-7626

SERVICE NOTE

To remove Blower Assembly: Unplug motor (7). 

Remove screw (4)  from motor plate (9) 

fl

 ange. Find 

the single 

TAB

 on the motor plate (located next to 

the receptacle). Push up near motor plate tab while 

pushing out on side of housing. Or insert a straight-

blade screwdriver into slot in housing (next to tab) 

and twist screwdriver.

Содержание QTXEN110H

Страница 1: ...SIVE CLOTH STEEL WOOL PADS OR SCOURING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor OPERATION The humidity control and fan can be operated separately Use a 1 or 2 funct...

Страница 2: ...CER use for mounting to I Joist TABS I JOIST highest holes NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each mounting flange and the I joist OR ROOF CAP...

Страница 3: ...und hanger bars SCREW 2 HOLE FOR OPTIONAL SCREW MOUNTING 4 MOUNTING CHANNEL 2 NAIL 4 BOTTOM EDGE OF FRAMING 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL...

Страница 4: ...S AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by...

Страница 5: ...ttoyants de solvants ou de l eau sur ou pr s du capteur FONCTIONNEMENT La commande d humidit et de ventilation peuvent fonctionner s par ment Utiliser la commande murale 1 ou 2 fonctions Ne pas utilis...

Страница 6: ...es pour plier les PATTES du bo tier 90 Maintenir le bo tier en place afin que les pattes du bo tier touchent au bas de la solive Le bo tier est install l aide de quatre 4 vis ou clous Visser ou clouer...

Страница 7: ...120 V c a jusqu l emplacement de l installation Utiliser un connecteur appropri et homologu UL pour fixer le fil d alimentation la plaque de branchement Brancher les fils tel qu il est illustr dans l...

Страница 8: ...S STARTERS DE LAMPES FLUORESCENTES ET LES TUBES Cette garantie ne couvre pas a l entretien et le service normal ou b tout produit ou pi ce endommag s la suite d un mauvais usage de n gligence d un ac...

Отзывы: