background image

Page 1

MODEL   QTXEN110H  

WARNING  

  

TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended 

by the manufacturer. If you have questions, 

contact the manufacturer at the address or 

telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch 

power off at service panel and lock the 

service disconnecting means to prevent 

power from being switched on accidentally. 

When the service disconnecting means 

cannot be locked, securely fasten a prominent 

warning device, such as a tag, to the service 

panel.

3.  Installation work and electrical wiring must be 

done by a quali

fi

 ed person(s) in accordance 

with all applicable codes and standards, 

including 

fi

 re-rated construction codes and 

standards.

4. Sufficient air is needed for proper 

combustion and exhausting of gases through 

the 

fl

 ue (chimney) of fuel burning equipment to 

prevent backdrafting. Follow the heating 

equipment manufacturer’s guideline and 

safety standards such as those published 

by the National Fire Protection Association 

(NFPA), and the American Society for Heating, 

Refrigeration and Air Conditioning Engineers 

(ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do 

not damage electrical wiring and other hidden 

utilities.

6.  Ducted fans must always be vented to the 

outdoors.

7.  Acceptable for use over a tub or shower when 

connected to a GFCI (Ground Fault Circuit 

Interrupter) - protected branch circuit.

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use 

to exhaust hazardous or explosive materials 

and vapors.

2. This product is designed for installation in 

fl

 at ceilings only. DO NOT MOUNT THIS 

PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy 

and/or unbalanced impellers, keep drywall 

spray, construction dust, etc. off power unit.

4. Please read speci

fi

 cation label on product for 

further information and requirements.

MODEL QTXEN110H

HUMIDITY SENSING FAN

READ AND SAVE THESE INSTRUCTIONS

CLEANING & 
MAINTENANCE

Installer: Leave this manual 

with the homeowner.

For quiet and ef

fi

 cient operation, long life, 

and attractive appearance - lower or remove 

grille and vacuum interior of unit with the 

dusting brush attachment.
The motor is permanently lubricated and 

never needs oiling. If the motor bearings are 

making excessive or unusual noises, replace 

the motor with the exact service motor. 

The impeller should also be replaced.

SENSOR CLEANING

The humidity sensor is mounted in the grille. 

The sensor will operate most reliably when 

cleaned occasionally as follows:

1. Disconnect power at service entrance.
2. Remove the grille. Use a dry dustcloth, 

clean toothbrush, or lightly vacuum to 

clean sensor and grille. DO NOT USE 

ABRASIVE CLOTH, STEEL WOOL 

PADS, OR SCOURING POWDERS.

3.  DO NOT USE cleaning sprays, solvents, 

or water on or near the sensor!

OPERATION

The humidity control and fan can be 

operated separately. Use a 1- or 2-function 

wall control. Do not use a dimmer switch to 

operate the humidity control or light. See 

“Connect Wiring” for details.

SENSOR OPERATION

T h e   h u m i d i t y - s e n s i n g

 

f a n   u s e s   a 

sophisticated humidity sensor that responds 

to: (a) rapid to moderate (user-adjustable) 

increases in humidity or (b) humidity above 

a user-adjustable set-point (50%-100% 

relative humidity). The humidity sensor 

may occasionally turn the fan ON when 

environmental conditions change. If the 

fan continuously responds to changing 

environmental conditions, “SENSITIVITY” 

adjustment may be required.

MANUAL ON WITH TIMED OFF

The humidity sensing fan has an 

additional operation feature. For odor or vapor 

control, the fan can be energized by cycling 

the power switch. Once the fan has been 

energized in this manner, it will remain on 

for the user-adjustable “TIMER” period 

(5 to 60 minutes). This period is factory-set 

for 20 minutes.
To manually energize the fan:

1. If fan power switch is already ON, 

proceed to Step 2; otherwise, turn power 

switch ON for more than 1 second.

2.  Turn fan power switch OFF for less than 

1 second.

3.  Turn fan power switch back ON and fan 

will turn ON.

SENSITIVITY ADJUSTMENT

The “SENSITIVITY” has been factory set 

for most shower applications. However, 

if the fan is in a tub area or is being used 

for dampness control, the “SENSITIVITY” 

may need to be increased toward maximum 

(“MAX.”). If the control is responding too 

often to changing environmental conditions, 

movement toward less (“MIN.”) “SENSITIVITY” 

may be required.
To adjust the “SENSITIVITY”:

1. Disconnect power at service entrance.
2.  Through the grille, locate the screwdriver 

slot marked “SENSITIVITY”.

3. Using a small, 

fl

 at-blade  screwdriver, 

carefully rotate the “SENSITIVITY” 

adjustment toward “MAX.” or “MIN.”

4. Turn on power and check operation by 

turning on the shower or other humidity 

source until the fan turns on.

5. Repeat above steps if necessary.

TIMER  ADJUSTMENT

The humidity sensing fan has a “TIMER” 

that can be adjusted from 5 to 60 minutes 

(factory-set at 20 minutes). This “TIMER” 

controls the length of time that the fan 

remains ON (a) after the sensor has 

stopped sensing a rise in humidity and the 

humidity level is below the user-adjustable 

set-point or (b) after being energized by 

cycling the power switch.
To adjust the “TIMER”:

1. Disconnect power at service entrance.
2.  Through the grille, locate the screwdriver 

slot marked “TIMER”.

3. Using a small, 

fl

 at-blade  screwdriver, 

carefully rotate the “TIMER” adjustment 

to desired setting (from 5 to 60 

minutes).

4. Check operation by cycling the power 

switch as instructed under “MANUAL 

ON WITH TIMED OFF” or by turning 

on a humidity source until the fan turns 

on.

5. Turn humidity source off and time the 

unit.

6. Repeat above steps if necessary.

Содержание QTXEN110H

Страница 1: ...SIVE CLOTH STEEL WOOL PADS OR SCOURING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor OPERATION The humidity control and fan can be operated separately Use a 1 or 2 funct...

Страница 2: ...CER use for mounting to I Joist TABS I JOIST highest holes NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each mounting flange and the I joist OR ROOF CAP...

Страница 3: ...und hanger bars SCREW 2 HOLE FOR OPTIONAL SCREW MOUNTING 4 MOUNTING CHANNEL 2 NAIL 4 BOTTOM EDGE OF FRAMING 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL...

Страница 4: ...S AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by...

Страница 5: ...ttoyants de solvants ou de l eau sur ou pr s du capteur FONCTIONNEMENT La commande d humidit et de ventilation peuvent fonctionner s par ment Utiliser la commande murale 1 ou 2 fonctions Ne pas utilis...

Страница 6: ...es pour plier les PATTES du bo tier 90 Maintenir le bo tier en place afin que les pattes du bo tier touchent au bas de la solive Le bo tier est install l aide de quatre 4 vis ou clous Visser ou clouer...

Страница 7: ...120 V c a jusqu l emplacement de l installation Utiliser un connecteur appropri et homologu UL pour fixer le fil d alimentation la plaque de branchement Brancher les fils tel qu il est illustr dans l...

Страница 8: ...S STARTERS DE LAMPES FLUORESCENTES ET LES TUBES Cette garantie ne couvre pas a l entretien et le service normal ou b tout produit ou pi ce endommag s la suite d un mauvais usage de n gligence d un ac...

Отзывы: