Page 2

MODELS   QTXEN050 • QTXEN080 • QTXEN110

TYPICAL INSTALLATIONS

Housing mounted 
to 

I

-joists.

Housing mounted 
anywhere be-
tween trusses us-
ing hanger bars.

PLAN THE INSTALLATION

*Purchase

separately.

INSULATION* 

(Place around and 

over Fan Housing.)

ROOF CAP*

(with built-in

damper)

FAN

HOUSING

POWER

CABLE*

6-IN. ROUND

DUCT*

6-IN.

ROUND

ELBOWS*

Seal gaps

around

Housing.

Seal duct

joints with

tape.

OR

Keep duct

runs short.

   WALL CAP* 

(with built-in

damper)

The ducting from this fan to the outside of the building has a strong 
effect on the air flow, noise and energy use of the fan. Use the 
shortest, straightest duct routing possible for best performance, 
and avoid installing the fan with smaller ducts than recommended. 
Insulation around the ducts can reduce energy loss and inhibit 
mold growth. Fans installed with existing ducts may not achieve 
their rated airflow.
Use a roof cap or wall cap that has a built-in damper to reduce 
backdrafts.
Plan to supply the unit with proper line voltage and appropriate 
power cable.

Housing mounted 
anywhere be-
tween 

I

-joists 

using 
hanger bars.

Housing mounted 
to joists.

Housing mounted 
anywhere be-
tween 
joists 
using 
hanger bars.

Housing mounted 
anywhere be-
tween trusses us-
ing hanger bars.

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.