Page 2
MODELS QTXEN050 • QTXEN080 • QTXEN110
TYPICAL INSTALLATIONS
Housing mounted
to
I
-joists.
Housing mounted
anywhere be-
tween trusses us-
ing hanger bars.
PLAN THE INSTALLATION
*Purchase
separately.
INSULATION*
(Place around and
over Fan Housing.)
ROOF CAP*
(with built-in
damper)
FAN
HOUSING
POWER
CABLE*
6-IN. ROUND
DUCT*
6-IN.
ROUND
ELBOWS*
Seal gaps
around
Housing.
Seal duct
joints with
tape.
OR
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
The ducting from this fan to the outside of the building has a strong
effect on the air flow, noise and energy use of the fan. Use the
shortest, straightest duct routing possible for best performance,
and avoid installing the fan with smaller ducts than recommended.
Insulation around the ducts can reduce energy loss and inhibit
mold growth. Fans installed with existing ducts may not achieve
their rated airflow.
Use a roof cap or wall cap that has a built-in damper to reduce
backdrafts.
Plan to supply the unit with proper line voltage and appropriate
power cable.
Housing mounted
anywhere be-
tween
I
-joists
using
hanger bars.
Housing mounted
to joists.
Housing mounted
anywhere be-
tween
joists
using
hanger bars.
Housing mounted
anywhere be-
tween trusses us-
ing hanger bars.
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.