OPERATIONAL CHECKOUT (Continued)
9
Placing the Master Cover Over the
Master Base
Position the top of the cover onto the top of the base.
When the cover and base are aligned, press on the front
cover until the cover snaps over the base.
Resetting the Microprocessor
If the intercom system does not operate properly, the internal
microprocessor may require resetting. There are three (3)
levels of resetting that have been incorporated into the
intercom system.
1.
To reset a remote station
, press *9# on the station's
keypad. This will reset the microprocessor in that
particular remote station only.
2.
To reset the
master
, locate the
lowest hole on the
right hand side of
the panel directly in
front of the panel
slot. Using a pencil
or pen point, press
the reset switch
through the hole.
3.
To reset the
complete system
,
remove the cover
from the base of
the master unit.
Locate the
POWER
switch in
the upper left corner of the master and toggle to the
OFF
position. Wait 30 seconds. Return the power switch to the
ON
position.
Tone Generator Volume
Adjustment
The tone generator creates the tones that are heard from
each station (call tone, error tone, feedback tone).
A trimpot is located at each remote station to allow custom
level adjustment.
To adjust the level at a particular station:
1. Enter an invalid keypad entry: Example: 3
2. Locate the ringer trimpot access hole next to the black wire
connection terminal.
3. Adjust the trimpot to the desired level using a small
screwdriver.
Completing the Installation
Check (
√
) all items below for final system check.
❏
Master unit is properly aligned and securely installed.
❏
All connections at the master are correct.
❏
All screw terminals have proper clearance.
❏
Remote station identifications are set.
❏
Optional chime/pushbuttons are properly connected and
functioning.
❏
All volume controls are satisfactory.
❏
Master unit is properly earth grounded.
❏
Power has been applied at the circuit breaker and at the
master.
❏
Station identifications are documented for the homeowner
and are in hand.
❏
Warranty card is in hand.
❏
Homeowner's instructions are in hand.
❏
Installation Instructions are in hand.
❏
The above four (4) items are grouped together for transfer
to the homeowner.
❏
Items delivered. Installation complete.
MASTER COVER
Lowest
hole on
the right
hand
side of
the
panel,
directly
in front
of the
panel
slot