2
IM-5000 SPECIFICATIONS
CONTENTS OF CARTON
Check (
√
) for the following IM-5000 carton contents:
❏
IM-5000 Selective Call Intercom
❏
Two (2) #8 x 1-1/4" wood screws
❏
Installation Instructions
❏
Homeowner's Manual
❏
Registration card
WIRING SPECIFICATIONS
Use NuTone IW-6, 22 ga, 3-twisted pair for connecting:
• Master to IC-502 remote controls
• Master to IS-515, IS-518 & IS-519 remote stations
Use NuTone IW-2, 22 ga. twisted pair for connecting:
• Door speakers
• Remote controls to speakers
• Electronic chime audio to master
Use NuTone S-143, 18 ga. twisted pair for connecting:
• Master to 401T power transformer
• Chime module or electronic chime to pushbutton
• Electronic chime to chime transformer
Use 14 ga. ground wire (not supplied by NuTone) for
connecting:
• Master to ground
Use shielded audio cable for connecting:
• External audio source
SYSTEM SPECIFICATIONS
• Power transformer: (1) NuTone 401T (24VAC @ 40VA)
• Maximum number of remote controls/stations:
20
• Maximum number of door speakers:
3
• Total system length of IW-6 cable:
4,000 ft.
• Maximum remote station cable length:
750 ft.
• Maximum IW-6 cables connected at master:
6
• Maximum number of remote stations per run:
6
• Total system length of IW-2 to door speakers:
750 ft.
• Maximum length of IW-2 to electronic chime:
200 ft.
• Maximum length of IW-2 from remote control to speaker:
25 ft.
• Maximum length of S-143 for 401T power transformer:
50 ft.
• Maximum length of S-143 for chime module pushbutton:
300 ft.
• Maximum length of S-143 for electronic chime transformer:
50 ft.
• Maximum length of S-143 for electronic chime pushbutton:
100 ft.
• Maximum length of shielded audio cable:
50 ft.
Note to Installer:
Do not discard these
instructions. Please give all installation
instructions, warranty registration and