PLANNING

Installing a bathroom exhaust fan-light in a finished house

requires at least a small accessible area (attic or crawl space)
above the planned installation location.

Review “INSTALLATION IN A NEW CONSTRUCTION

SITE” AND FOLLOW ALL INSTRUCTIONS WHICH APPLY
TO YOUR INSTALLATION.

LOCATION:

Locate fan-light next to a ceiling joist.

WIRING AND DUCTING: Refer to Figures 5 and 6 for
wiring and to Figure 4 for ducting.

Plan ducting and wiring

before proceeding with installation.

CAUTION: Check area above planned location to be sure
that:

(1) Ducting can be installed or that area is sufficient for

proper venting. The ceiling joists should run toward an
outside wall.

(2) Wiring can be run to the planned location.
(3) No wiring or other obstruction might interfere with

installation.

INSTALLATION

1. The fan light must be mounted to a ceiling joist. Decide

where you want to locate the fan-light and then determine
if there is a ceiling joist near.

LOCATING JOIST:

Lightly tap the ceiling. A hollow sound

means no joists, a solid sound means a joist is present. To
be sure you have located a joist, drill a small hole (

1

16

") and

probe into the ceiling with a wire. Leave wire in hole to help
locate it in the attic or crawl space.

2. Locate hole in attic or crawl space. Make sure hole is

within 9" of joist.

3. From below, saw a line from hole to joist.
4. Using the housing as a template, mark the ceiling for the

cutout. Cutout dimensions: 9

1

8

" x 9

1

8

". One side of cutout

must be right next to joist.

5. Make cutout along marked line.
6. In attic or crawl space, run 4" round duct from outside to

cutout location.

7. Run wiring to cutout location.
8. Place housing into cutout and secure housing to joist.

Make sure housing is flush with finished ceiling. Connect
duct.

9. From below, connect wiring. Install power/blower unit,

grille/reflector assembly, fluorescent lamp and lens.

INSTALLATION IN EXISTING CONSTRUCTION

One Year Limited Warranty

WARRANTY OWNER: 

NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period

of one (1) year from the date of original purchase. 

THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED

WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

During this one year period,

NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. 

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES
FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,
improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.  

The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.

NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may

not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. 

WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.

Date of Installation

Builder or Installer

Model No. and Product Description

IF YOU NEED ASSISTANCE OR SERVICE:

For the location of your nearest NuTone Independent Authorized Service Center:

Residents of the contiguous United States 

Dial Free 1-800-543-8687

Please be prepared to provide: 

Product model number • Date and Proof of purchase • The nature of the difficulty

Residents of Alaska or Hawaii should write to:

NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.

Residents of Canada should write to:

Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada    L5T 1H9.

Rev. 03/2001

Содержание 769RF

Страница 1: ...ccordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning eq...

Страница 2: ...NG THE HOUSING USING SIDE MOUNTING TABS Refer to Figure 2 1 Locate housing next to ceiling joist 2 Use wood screws not provided to loosely attach housing to ceiling joist through keyhole slots in moun...

Страница 3: ...BLOWER UNIT INSTALLATION Refer to Figure 7 1 Place power blower unit into housing so that mounting plate s tabs insert into slots in housing 2 Press other end of mounting plate down until it is firml...

Страница 4: ...PRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period NuTone will at its option repair or replace without...

Страница 5: ...EEL 769RF 82403 000 4 87549 REFLECTOR ASSEMBLY 769RF 87549 000 5 30652 DUCT ADAPTER ASSEMBLY 769RF 30652 000 6 85315 GRILLE AND LENS ASSEMBLY 769RF 85315 000 7 16133 WING NUT 769RF 16133 000 8 10034 F...

Страница 6: ...s ou des vapeurs INSTRUCTIONS D INSTALLATION MISE EN GARDE POUR REDUIRE LE RISQUE D INCENDIE D ELECTROCUTION OU DE BLESSURE PHYSIQUE RESPECTEZ LES OBSERVATIONS SUIVANTES A L installation et les c blag...

Страница 7: ...f rer la figure 2 1 Placez le bo tier c t de la solive du plafond 2 Utilisez des visses en bois non fournies pour attacher le bo tier l chement la solive du plafond travers les fentes dans les pattes...

Страница 8: ...rer la figure 7 1 Placez l unit de courant ventilateur dans le bo tier pour monter les pattes de la plaque dans les fentes du bo tier 2 Poussez l autre extr mit de la plaque de montage vers le bas ju...

Страница 9: ...pour une p riode d un 1 an compter de la date d achat AUCUNE AUTRE GARANTIE IMPLICITE OU EXPRESSE N EST DONN E Y COMPRIS MAIS SANS S Y LIMITER GARANTIE DE MARCHANDIBILIT OU D ADAPTATION UN USAGE PARTI...

Страница 10: ...RF 82403 000 4 87549 ASSEMBLAGE DU REFLECTEUR 769RF 87549 000 5 30652 ASSEMBLAGE DE L ADAPTATEUR DE LA GAINE 769RF 30652 000 6 85315 ASSEMBLAGE GRILLE ET LENTILLE 769RF 85315 000 7 16133 ECROU A AILET...

Отзывы: