IMPORTANT INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE INSTALLING OR 

USING THIS  HEATER.

To reduce the risk of fire, electric shock, or injury to persons, observe the 

following:

1. Use this unit only in the manner intended by the manufacturer. If you have 

questions, contact the manufacturer at the address or telephone number 

listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel and 

lock the service disconnecting means to prevent power from being 

switched on accidentally. When the service disconnecting means cannot 

be locked, securely fasten a prominent warning device, such as a tag, to 

the service panel.

3. Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, includ-

ing fire-rated construction codes and standards.

4. When cutting or drilling into wall or ceiling, do not damage electrical wiring 

and other hidden utilities.

5. This heater is hot when in use. To avoid burns, do not let bare skin touch 

hot surfaces. Keep combustible materials, such as furniture, pillows, bed-

ding, papers, clothes, etc. and curtains at least 3 feet (0.9 m) from the 

front of the heater.

6. Extreme caution is necessary when any heater is used by or near chil-

dren or invalids and whenever the heater is left operating and unattended.

7. Do not operate any heater after it malfunctions. Disconnect power at ser-

vice panel and have heater inspected by a reputable electrician before 

reusing.

8. Do not use outdoors.
9. To disconnect heater, turn controls to off, and turn off power to heater 

circuit at main disconnect panel (or operate internal disconnect switch, if 

provided).

10. Do not insert or allow foreign objects to enter any ventilation or exhaust 

opening, as this may cause an electric shock or fire, or damage the heat-

er.

11. To prevent a possible fire, do not block air intakes or exhaust in any man-

ner.

12. A heater has hot and arcing or sparking parts inside. Do not use it in 

areas where gasoline, paint, or flammable vapors or liquids are used or 

stored.

13. Use this heater only as described in this manual. Any other use not rec-

ommended by the manufacturer may cause fire, electric shock, or injury 

to persons.

14. This product must be grounded.
15. Do not install heater in a tub or shower enclosure.
16. THIS PRODUCT MUST BE MOUNTED IN A FLAT CEILING ONLY. In-

stallations in ceilings 9-feet high or less will provide maximum comfort. 

DO NOT MOUNT THIS PRODUCT IN A WALL.

17. Install heater in ceiling only - at least 6 inches from any wall.
18. Do not connect heater to dimmer switch or speed control.
19. Provide a separate 20 AMP circuit. Use 12 GA. power cable of type which 

meets code. Use supply wiring rated for at least 90

O

C.

20. For greatest efficiency, install heater so heat is directed toward tub or 

shower area.  Avoid directing toward walls or windows.

SAVE THESE INSTRUCTIONS

PLAN THE INSTALLATION

The unit will operate most quietly and efficiently when located 
where the shortest possible duct run and minimum number of 
elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce 
backdrafts.
Plan to supply the unit with proper line voltage and appropriate 
power cable.

ROOF

CAP 

*

4-IN. ROUND

ELBOW(S) 

*

4-IN.

ROUND

DUCT

*

WALL

CAP 

*

*

 Purchase

separately

INSULATION

(Can be placed 

around and over 

housing.)

HOUSING

TYPICAL INSTALLATION

HOUSING

CEILING

JOIST, TRUSS, 

OR I-JOISTS 

MOUNTING

CHANNELS

GRILLE

CEILING

MATERIAL 

POWER 

CABLES

Housing mounted to joists, trusses, or I-joists. 

Up to 24-inches on-center.

Содержание 765HFL

Страница 1: ...cuit at main disconnect panel or operate internal disconnect switch if provided 10 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shoc...

Страница 2: ...OF FRAMING SCREW 2 HOLE FOR OPTIONAL SCREW MOUNTING 4 NAIL 4 WARNING To reduce the risk of fire do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater CAUTIO...

Страница 3: ...t wires as shown in wiring diagram s B L U B L K B L K W H T W H T W H T R E D W H T G R D U N I T L I G H T S W I T C H V E N T S W I T C H H E A T S W I T C H L I N E I N R E D B L K W H T B L K W H...

Страница 4: ...eater make sure heater has been properly installed according to installation steps beginning with the TYPICAL IN STALLATION section on page 1 Use a 3 Function Control to operate the heater fan and lig...

Страница 5: ...LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequenti...

Страница 6: ...Heater Element 19 99080606 Heater Motor 20 99020293 Fan Wheel 21 98010089 Heating Element Mounting Bracket 22 99080602 Fan Motor 23 99100491 Isolator Bushing 4 req 24 97017606 Partition Assembly 25 9...

Страница 7: ...n principal o active el interruptor de desconexi n interna si existe 10 No inserte ni permita que objetos extra os entren en la abertura de ventilaci n o de escape pues esto puede ocasionar una descar...

Страница 8: ...da LENG ETA CANAL BARRAS DE SUSPENSI N BARRAS DE SUSPENSI N CANAL BORDE INFERIOR DE LA ESTRUCTURA TORNILLO 2 ORIFICIO PARA MONTAJE OPCIONAL CON TORNILLO 4 CLAVO 4 ADVERTENCIA Para reducir el riesgo de...

Страница 9: ...eado A Z U L N E G R O B L A N C O T I E R R A U N I D A D I N T E R R U P T O R D E L U Z I N T E R R U P T O R D E L V E N T I L A D O R I N T E R R U P T O R D E L C A L E FA C T O R L N A E A D E...

Страница 10: ...de que est instalado ad ecuadamente de acuerdo con los pasos de instalaci n indicados en INSTALACI N TYPICA en la p gina 7 Utilice un control de 3 funciones para operar el calefactor el ventilador y l...

Страница 11: ...SECUENCIA O SEAN INDEPENDIENTES DEL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes de modo que la limitaci n o exclusi n arriba...

Страница 12: ...ucto 4 pulg Panel el ctrico de agujeros ciegos Tornillo No 8 18 x 0 375 pulg se requieren 5 Tornillo de tierra No 10 32 X 0 500 PH HWH se requieren 2 Conjunto del panel de cableado Clip de cable Torni...

Отзывы: