2. Mark mounting location.

Position unit between joists and extend mounting brackets. 
IMPORTANT: Position brackets so there will be an 1/8” gap 
between bottom of housing and ceiling material.
 Mark the top 
of keyhole slot on all four mounting brackets.

1/8" GAP

1. Install mounting brackets.

Slide the adjustable mounting brackets into the bracket channels 
on the housing.
Bend the tabs on the cardboard protector and insert protector 
into opening in housing.
NOTE: The cardboard protector shields the inside of the housing 
from drywall spray and construction dust. Do not remove it until 
after construction is completed.

CARDBOARD PROTECTOR

3. Pound in nails.

Remove unit temporarily, and pound nails partially into joists at 
all four marked locations.

HOUSING

MOUNTING

BRACKET

CEILING

JOIST

POWER

CABLE

TRIM RING / BAFFLE

FINISHED CEILING

4" ROUND

DAMPER/DUCT

CONNECTOR &

4” ROUND

DUCTWORK

PLAN THE INSTALLATION

The unit can be installed anywhere between ceiling joists using mounting 

brackets provided. Install in a flat ceiling only.

Typical Installation

The unit must not be installed above or inside the cooking area shown.

Do not install in a cooking area.

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.

The unit will operate most quietly and efficiently when located where 

the shortest possible duct run and minimum number of elbows will be 

needed.
Use a roof cap or wall cap that has a built-in damper to reduce backdrafts.
Plan to supply the unit with proper line voltage and appropriate  

power cable.

*Purchase

separately.

INSULATION* 

(Place around and 

over Fan Housing.)

ROOF CAP*

(with built-in

damper)

FAN

HOUSING

POWER

CABLE*

4-IN. ROUND

DUCT*

4-IN.

ROUND

ELBOWS*

Seal gaps

around

Housing.

Seal duct

joints with

tape.

OR

Keep duct

runs short.

   WALL CAP* 

(with built-in

damper)

Содержание 744SFLNT

Страница 1: ...peration by turning on shower or other humidity source until fan turns on 7 Repeat above steps if necessary TIMER ADJUSTMENT This humidity sensing fan has a timer It is user adjustable from 5 to 60 mi...

Страница 2: ...TRIM RING BAFFLE FINISHED CEILING 4 ROUND DAMPER DUCT CONNECTOR 4 ROUND DUCTWORK PLAN THE INSTALLATION The unit can be installed anywhere between ceiling joists using mounting brackets provided Instal...

Страница 3: ...llows the power cable to enter unit horizontally or vertically 7 Connect wiring Unit can be wired from outside of housing as shown Use UL approved connectors to wire per local codes BLK HUMIDITY CONTR...

Страница 4: ...d installed with the Fan The limited warranty period for replacement parts and for Fans repaired or replaced under this limited warranty shall continue for the remainder of the original warranty perio...

Страница 5: ...e courant et v rifiez le fonctionnement de l appareil en faisant couler la douche ou une autre source d humidit jusqu ce que le ventilateur d marre 7 R p tez les tapes ci dessus au besoin R GLAGE DE L...

Страница 6: ...2 CM 4 PO PLANIFICATION DE L INSTALLATION L appareil peut tre install partout entre les solives du plafond l aide des brides de montage incluses Ne l installez que dans un plafond plat Installation ty...

Страница 7: ...e c blage peut tre effectu l ext rieur du bo tier tel qu illustr Utilisez des connecteurs homologu s UL pour effectuer le c blage conform ment aux codes locaux COMMANDE 2 FONCTIONS VENDUE S PAR MENT O...

Страница 8: ...r les ventilateurs r par s ou remplac s en vertu de la pr sente garantie se poursuivra pendant le reste de la p riode de garantie originale CETTE GARANTIE NE COMPORTE AUCUNE AUTRE GARANTIE EXPRESSE OU...

Страница 9: ...o el interruptor de alimentaci n de acuerdo con las instrucciones contenidas en la secci n ENCENDIDO MANUAL CON APAGADO PROGRAMADO o encendiendo una fuente de humedad hasta que el ventilador se prenda...

Страница 10: ...REDONDO DE 4 PULG PLANEACI N DE LA INSTALACI N Esta unidad se puede instalar en cualquier lugar entre las vigas del cielo raso usando los soportes de montaje que se proporcionan Instale nicamente en u...

Страница 11: ...dor de tiro conducto en la cubierta Aseg rese de que las leng etas del conector queden fijas en las ranuras de la cubierta La parte superior del conector del regulador de tiro conducto quedar al ras c...

Страница 12: ...ta garant a no cubre accesorios como controles de velocidad que pueden comprarse por separado e instalarse con el ventilador Elperiododegarant alimitadaparalaspiezasderepuestoyparalosventiladoresrepar...

Отзывы: