OPI_TOP LIFT TSK 8000_V3.2_EN
Time frame
Maintenance
type position
Maintenance plan
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
All weld seams must have a visual inspection. Stop
the system and contact the manufacturer if there are
cracks or breaks in weld seams of the lift.
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
Check electrical components for function and con-
dition.
• Plug
• Operating lever with button switch
• During assembly and maintenance always check
the condition of electrical lines. All cables and lines
must be secured so they cannot be crushed, kinked
or contact any moving assembly.
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
Optional energy set:
• Electrical socket
• Pneumatic connection
Check for condition and function.
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
Check all fastening screws and anchors with a torque
wrench.
Fastening class 8.8
0.08* 0.12** 0.14***
M8
17.9 23.1 25.3
M10
36 46 51
M12
61 80 87
M16
147 194 214
M20
297 391 430
M24
512 675 743
Fastening class 10.9
0.08* 0.12** 0.14***
M8
26.2 34
37.2
M10
53 68 75
M12 90
117
128
M16
216 285 314
M20
423 557 615
M24
730 960 1060
*
Lubricated slide friction number 0.8 MoS2
**
Lightly oiled slide friction number 0.12
***
Ensured slide friction number 0.14 screw with micro-encap-
sulated plastic
Содержание TSK 8000
Страница 2: ...2 OPI_TOP LIFT TSK 8000_V3 2_EN...
Страница 4: ......
Страница 9: ...OPI_TOP LIFT TSK 8000_V3 2_EN 9...
Страница 20: ...20 OPI_TOP LIFT TSK 8000_V3 2_EN...
Страница 44: ...44 OPI_TOP LIFT TSK 8000_V3 2_EN...
Страница 45: ...TOP LIFT TSK 8000 Serial No Made in Germany Spare parts list...
Страница 51: ...OPI_TOP LIFT TSK 8000_V3 2_EN 51...