OPI_SMART LIFT 2.30 SL-2.35 SL-2.40 SL - HYMAX S 3000-S3500-S4000_V1.2_DE-EN-FR-ES-IT
105
LED displays for malfunctions of the lift
Bottom end position of the lift rails
Desired position of the lift rails
between the end positions
Top end position of the lift rails
Possible cause of fault
Operator side not plugged in. (P1 NOK)
Operator side not plugged in. (P2 NOK)
Operator and opposite side not plugged in. (P1 and P2 NOK)
Operator side not plugged in. (P1 NOK)
Operator side not plugged in. (P2 NOK)
Operator and opposite side not plugged in. (P1 and P2 NOK)
Operator side not plugged in. (P1 NOK)
Operator side not plugged in. (P2 NOK)
Operator and opposite side not plugged in. (P1 and P2 NOK)
Reverse switch turned to "Raise"
!Stop! UA1 illuminated UA2 illuminated “Raise” illuminates “Lower” illuminates
!Stop! UA1 illuminated UA2 illuminated “Raise” illuminates “Lower” illuminates
!*! K1 illuminated K2 illuminated UA1 illuminated UA2 illuminated “Raise” illuminated “Lower” illuminates
!Stop! “Raise” illuminates “Lowerer” illuminates UA1 illuminated
!Stop! “Raise” illuminates “Lowerer” illuminates UA2 illuminated
!*! K1 illuminated K2 illuminated UA1 illuminated UA2 illuminated “Raise” illuminated “Lower” illuminates
!Stop! UA1 illuminated UA2 illuminated “Raise” illuminates “Lower” illuminates
!Stop! OA1 continuous
-
ly illuminated UA2 continuous
-
ly illuminated “Raise” illuminates “Lower” illuminates
!*! K1 illuminated K2 illuminated UA1 illuminated UA2 illuminated “Raise” illuminated “Lower” illuminates
Reverse switch turned to "Lower"
!Stop! UA1 illuminated UA2 illuminated “Raise” illuminates “Lower” illuminates
!Stop! UA1 illuminated UA2 illuminated “Raise” illuminates “Lower” illuminates
!Stop! UA1 illuminated UA2 illuminated “Raise” illuminates “Lower” illuminates
!Stop! “Raise” illuminates “Lowerer” illuminates UA1 illuminated
!Stop! “Raise” illuminates “Lowerer” illuminates UA2 illuminated
!Stop! UA1 illuminated UA2 illuminated “Raise” illuminates “Lower” illuminates
!Stop! UA1 illuminated UA2 illuminated “Raise” illuminates “Lower” illuminates
!Stop! UA1 continuous
-
ly illuminated UA2 continuous
-
ly illuminated “Raise” illuminates “Lower” illuminates
UA1 illuminated UA2 illuminated “Raise” illuminated “Lower” illuminates
Comment: If only the two LEDs „Raise“ and „Lower“ illuminate and the lift can no longer be moved, then the lift is out of monitoring range
Legend: E.g. „UA1 illuminated“
LED for „Bottom off“ is illumina
ted.
E.g. „Raise illuminates“
LED for „Raise“ illuminates.
P1 NOK
Potentiometer 1 on the opera
tor side is not plugged in or supply line interrupted
P2 NOK
Potentiometer 2 on the oppo
site side is not plugged in or supply line interrupted
P1 or P2NOK
Potentiometer 1 on the opera
tor side or Potentiometer 2 on the opposite side is not plugged in or interrupt supply line.
P1
and
P2
NOK
Potentiometer
1 on the operator side
and Potentiometer
2 on the opposite side
are not plugged in or supply
line interrupted.
!*!
Warning: Lift only moves upw
ards, lowering is not possible: There is a risk that the lift block moves.
!Stop!
Lift does not move in the desi
red direction according to the actuation of the reverse switch, but remains stopped
Содержание ATT HYMAX S 3000
Страница 17: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 87...
Страница 18: ...88 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT...
Страница 20: ...90 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT...
Страница 21: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 91...
Страница 23: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 93...
Страница 24: ...94 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 3 4 Foundation plans...
Страница 26: ...96 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT...
Страница 27: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 97...
Страница 28: ...98 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT...
Страница 29: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 99...
Страница 30: ...100 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT...
Страница 98: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 375...