7 Trouble Shooting
x
If malfunctions occur, the following list facilitates the recognition of the causes of malfunctions.
x
Before the elimination of malfunctions and repairs, the safety regulations are to be followed.
x
When the EASY-PRINT is ready for operation the green led is on.
Malfunction
Problem
Action
EASY-PRINT does not
operate. LED not
illuminated.
Main power to packer is switched off.
EASY-PRINT is switched off.
Connector is not plugged in.
- Switch on main power to grader.
-
Switch machine on.
-
Plug in connector.
EASY-PRINT does not
operate.
The protective cover is closed [OFF] or
not completely opened.
Cover has to be closed [OFF] when the
EASY-PRINT is switched on.
- Open the protective cover
completely. [ON]
EASY-PRINT does not
operate.
Safety lid is not completely closed.
- Close safety-lid.
More information about the status of the green LED can be found on page 6.
Caution:
x
The wires in the control box are under high voltage. Open the electrical cabinet only when the main
plug has been pulled out.
8 Cleaning, Maintenance, Repair
8.1 Cleaning
Clean machine periodically, at least weekly, depending on the accumulation of dirt.
Before cleaning, the machine power switch must be in the off position.
The power supply plug has to be pulled out of the socket.
Never submerge the machine in water or in other liquids.
Cleaning personnel are to be instructed on approved procedures.
8.2 Maintenance
With careful monitoring and maintenance of the machine, disassembly will be necessary only to replace worn
parts. If other malfunctions nevertheless occur, the causes are to be determined first.
Before maintenance, the machine is to be switched off properly.
8.3 Repair
In case of malfunctions, due to a defective device component the main switch must be turned off.
Before repair, the machine is to be switched off and disconnected from the power supply.
Never put a damaged device into operation.
Reaching into the device with any object or opening the machine by unauthorized persons is dangerous.
Mechanical and electrical repairs or changing parts on the machine and controller shall be performed only by
technical personnel of the authorized service centre or by trained maintenance engineers. No other person may
perform repairs or change parts on the machine.
Spare parts must comply with the technical requirements established by the manufacturer. Original spare parts
are to be used as listed in section 12
‘Spare Parts’
.
Caution: The following is to be observed when opening the control housing cover:
x
Open the cover only after the main plug has been pulled out.