Edition 00 to 01/2018
4.5
SERVICE MANUAL
6
Press the down arrow and let go before the
blade begins to be expelled.
7
Remove the central seeger from the lower pis-
ton shaft.
6
7
8
Slide out the piston out from the top.
9
Using a Flathead screwdriver, take out
the screw securing the shower to the pis-
ton clean the shower with a damp cloth
or leave to soak in hot water and Pulicaff.
If the shower is too dirty, replace it with a new one.
Make sure that the piston surface are clean.
10
With a 21 mm wrench, undo the screw that
holds the seal.
8
10