65
ENGLISH
STANDARD DOSE PROGRAMMING
• Setting predetermined values for the four
doses of the first delivery unit is not possible.
To do so, you must:
• Press the first unit continuous delivery
key and keep pressing it for at least 8 sec-
onds, until the flashing delivery keys of the
first unit turn off.
• The standard doses are illustrated in the fol-
lowing table:
40 cc
60 cc
50 cc
85 cc
9 sec.
0 sec.
NOTE: A time of 0 seconds for water and steam
give way to their continuous functioning.
DOSE COPYING
This procedure must be carried out for each unit
individually by pressing the
continuous
delivery key of the unit you desire to copy the
doses onto and keep pressing it for at least 8
seconds, until the flashing delivery keys turn off.
AUTOMATIC CLEANING CYCLE
• To enter in the automatic cleaning cycle, you
must switch off the machine and switch on
the machine holding pressing
the
hot water and
cupwarmer keys during
the initial Lamp-test. At the end of the Lamp-
test, starts to blinking the
keys, and
the
(one long coffee) keys of each
groups.
• By pressing the
key starts the cleaning
cycle in the group selected. When the clean-
ing cycle is finished, is possible to begin the
rinsing cycle in the same group, by pressing
again the
key.
• If you want make the rinsing cycle in an other
time it's enough to switch off the machine:
the control board memorizes the cleaning
cycles that you must end. With the next turn
on, the control board will enter automatically
in the cleaning cycle, without pressing the
and
keys.
• By pressing the
and
keys for 2
seconds you escape from the cleaning cycle
in case there are not cycles to end, other-
wise the
keys of the group, in that you
must finish the rinsing cycle, remain with
blinking.
• By holding pressing the
and
keys for other 2 seconds you force the
escape from the cleaning cycle by resetting
the rinsing cycle.
• If the cleaning and the rinsing cycle is ended,
the
key of the group switch off; if there
are no cycles to finish, the machine return
ready.
7.5
PROGRAMMING
AURELIA ESSE
DOSE PROGRAMMING
In the Aurelia Esse version only the doses of
water and timed steam can be programmed.
To access the programming state you must:
• press the cup-warming key
for five
seconds..
• The selection keys and the 1 long coffee key
belonging to the first unit will start to
flash on and off while the other delivery keys
of the other units will turn off.
HOT WATER
• Once the programming state has been
accessed, by pressing the
key, hot
water delivery will be activated; once the
desired dose has been reached press the
key again and the set delivery time
will be stored in the control unit.
TIMED STEAM
• Once in the programming mode, pressing
the
key will enable steam dispensing
and once you have the required dose, press
the
key again and the control unit will
store the set dispensing time to memory.