The fuses blow or
circuit breaker
trips repeatedly.
The thermal
overload protector
cuts out repeatedly.
The incorrect fuse type is
being used.
The wrong gauge wire or
length of extension cord is
used.
There is a defective check
valve or unloader.
There is low voltage from
the power source.
There is a lack of proper
ventilation, or the room
temperature is too high.
The wrong gauge wire or
length of extension cord is
being used.
The connections (fittings,
tubing, etc.) are loose and
leaking.
The drain valve is loose or
open.
The check valve is leaking.
There is excessive water in
the air tank.
The compressor is working
under a high humidity
environment.
The air receiver
pressure drops
when the
compressor shuts
off.
There is excessive
moisture in the
discharged air.
Check for the proper
fuse.
Check for the proper
gauge wire and cord
length.
Bring the compressor
to a service center.
Call an electrician.
Move the compressor
to a well ventilated
area.
Check for proper
gauge wire and cord
length.
Check all connections
with a soap and water
solution and tighten.
Tighten the drain
valve.
Bring the compressor
to a service center.
Drain the tank.
Move the compressor
to an area of less
humidity; use an air
line filter.
Use a time-delay
fuse. Disconnect
other electrical
appliances from the
circuit or operate the
compressor on its
own branch circuit.
The motor hums
while running
slowly, or it
doesn't run at all.
Release the air from
the tank until the
compressor restarts
automatically.
Bring the compressor
to a service center.
Call an electrician.
Check for proper
gauge wire and cord
length.
Bring the compressor
to a service center.
Bring the compressor
to a service center.
The pressure switch is
bad.
The compressor has
reached automatic shutoff
pressure.
There is low voltage from
the power source.
The wrong gauge wire or
length of extension cord is
being used.
There is a shorted or open
motor wiring.
There is a defective check
valve or unloader.
PROBLEM
The Compressor
does not run.
POSSIBLE CAUSE
CORRECTIVE ACTION
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
14
15
The pressure switch is
defective.
An excessive amount of air
is being used.
The inlet valves are broken.
The connections (fittings,
tubing, etc.) are loose and
leaking.
The compressor
continuously runs.
The air output is
lower than normal.
Bring the compressor
to a service center.
Bring the compressor
to a service center.
Tighten the
connections.
Decrease the air
usage; the compres-
sor is not large enough
for the tool's require-
ment.