Brush pressure / Load adjustment

The brush load lever is located to the right hand side of the machine.

This option is for hard to clean patches, adding 10 kg extra pressure to the brushes.

 

The brush load indicator on the control display shows the pressure applied, when the 

machine is being operated. 

Load increases from 40 Kg (fig 24) to 50Kg  When the lever is in the up position. (fig 24a)

NOTE: It is recommended this option is NOT used all the time and is for spot cleaning only.

Fig.24

Fig.24 a

NOTE: The run-time of the machine may decrease 

if the load on the brushes is increased

Machine Operation

Waste water tank fill level warning light

When the waste water-tank becomes full, a  red warning light will 

illuminate on the operator control panel (as illustrated).

The vacuum motor will stop automatically after 5 seconds . 

The waste-water tank requires emptying (see page 17).

Emergency-stop button

The TTV - 5565 is equipped with an electronic braking system.

Simply release the hand operated start / stop trigger and the machine will stop.

In an emergency, strike the emergency-stop button.

The machine will be disabled.

To reset, turn Emergency Stop button clockwise (see fig.25).

After re-setting the emergency stop button, to restart the machine, turn the 

master control on/off key to the ‘OFF’ and then ‘ON’ position.

Fig.25

Содержание TTV-5565/200T

Страница 1: ......

Страница 2: ...re load adjustment Waste tank warning light Emergency stop button Breakaway floor tool feature Machine usage advice Off aisle cleaning kit optional Regular Maintenance Tanks and Filters Changing the F...

Страница 3: ...l 9 Semi parabolic floor tool 10 Brush deck aluminium 11 Chemical dosing tank 5 litre 12 Chemical dosing Pump 13 Water pump 14 Gel batteries 15 40 Amp battery fuses x2 16 Clean Water Filter 17 Waste w...

Страница 4: ...Instructions on control panel set up and use see machine operation page 14 15 Start Stop Trigger Speed Control Forward Reverse Switch 5 6 Water Flow Rate Adjustment 8 9 10 Chemical Mix Adjustment 11...

Страница 5: ...t for recovery in an Environmentally friendly manner Safety Critical Component Charging Lead H05VV F x 1 0 mm2 x 3 core Battery Charger 220 240 Volt PPE Personal protective equipment that may be requi...

Страница 6: ...CAUTION This machine is not suitable for picking up hazardous dust Do not use on surfaces having a gradient exceeding that marked on the appliance The machine is not to be stored outdoors in wet cond...

Страница 7: ...well ventilated area for charging Do not smoke or bring naked flames into the charging area 3 Remove any metallic items from hands wrists and neck i e rings chains etc before working on a battery 4 N...

Страница 8: ...artment ensuring you use the handle grip provided fig 1 Fit battery fuses contained in start up pack into the battery fuse holders as illustrated fig 2 Note Wear suitable gloves when inserting fuses F...

Страница 9: ...ollection pipe onto the floor tool ensure a tight fit fig 9 Note Raise floor tool again before driving to the cleaning area fig 9a Fig 8 Fig 9a Fig 9 Fig 7 Owning the TTV 5565 scrubber dryer is like h...

Страница 10: ...eck width setting is correct with the selected brushes before use Fig 12 Fig 13 Setting the width adjustment Adjustment of the Brush deck must take place with the deck in the raised position Lift the...

Страница 11: ...er tap or use a hose to com mence filling Fig 17 Or the tank can be filled by unscrewing the filler cap and using a bucket or similar container Fig 17a Note Great care must be taken to ensure that con...

Страница 12: ...mply fill the 5 litre chemical dosing bottle and the machine will deliver the correct mix ratio as set by the operator depending on the floor and cleaning conditions To fill the chemical dosing bottle...

Страница 13: ...ever see fig 20 to it s lower position see fig 21 Note The machine will still reverse with the Floor tool in the lowered position this could possibly damage the blades Raise the floor tool before sele...

Страница 14: ...o the ON position The battery charge level indicator will illuminate for 5 seconds 1L 2L 3L 4L 1 L Min 2 L Min 3 L Min 4 L Min 100 1 75 1 50 1 25 1 100 1 75 1 50 1 25 1 The TTV 5565 has been fitted wi...

Страница 15: ...he load on the brushes is increased Machine Operation Waste water tank fill level warning light When the waste water tank becomes full a red warning light will illuminate on the operator control panel...

Страница 16: ...lect water flow rate chemical mix see page 14 lower the floor tool see page 13 and select forward see page 8 fig 4 press the start stop trigger Vacuum pick up water flow and chemical dose will turn on...

Страница 17: ...will disable all the machine functions accept for the vacuum allowing for the use of the off aisle accessory kit Remove the vacuum hose from the floor tool and attach to the off aisle kit fig 30a Pres...

Страница 18: ...clean down Rinse using clean water avoiding the vac filter 31a IMPORTANT Remove white vac filter and clean if required keep dry fig 31a Never use the machine without the recommended filter as it may c...

Страница 19: ...tart by removing the four retaining pins see fig 33 turn the floor tool over and separate the blade carrier from the body see fig 34 Peel away the blades from their locating lugs see fig 35 and examin...

Страница 20: ...omatically be disabled and the operator should drive the machine straight to a suitable charge point The large capacity gel batteries are sealed for life and are totally maintenance free The on board...

Страница 21: ...ated on the left side of the machine near the rear wheel see fig 40 Pull the arm out see fig 41 Swing to the disengaged position see fig 42 The motor brake will be fully disengaged The machine will no...

Страница 22: ...arging Green Fully Charged Red Charging Stopped Automatically 27 hours MAX Remove Mains Supply Recharge the machine fully after its last use Do not leave the machine in a discharged state Under abnorm...

Страница 23: ...ater Flow rate Nuchem Mix Transit Speed Cleaning Speed Noise Max decibel level at 1 meter Maximum Climbing Gradient 3 5 Hrs 85L 5Lt 1L min 2L min 3L min 4L min 100 1 75 1 50 1 25 1 0 4 2Kph 0 4 2Kph 6...

Страница 24: ...ctions and replace damaged components check exhaust clean if necessary 3 Flashes with pause Traction motor wiring Trip The motor has a short circuit to a battery Motor will not operate Check all conne...

Страница 25: ...tery LED flashes Batteries require recharging Faulty cell on battery Machine will not operate Battery leads and connections Charge Bartteries page 19 Replace battery if cell dam aged TANK FULL Tank fu...

Страница 26: ...tact service dept Renew contact service dept Recharge batteries page 19 21 No brush scrub function No brushes fitted Brush deck raised Check and fit page 10 Lower brush deck page 13 Little or no water...

Страница 27: ...fuse 3 206953 Detent pin 9 BRUSHES 606253 HD Nyloscrub 2 req 330mm STANDARD 606252 HD Nyloscrub 2 req 280mm STANDARD 606174 Polyscrub 2 req 330mm 606173 Polyscrub 2 req 280mm 606172 Nyloscrub 2 req 3...

Страница 28: ...233887 06 11 A05 28 TTV 5565 WD 5329 A09 8 03 2011...

Страница 29: ...233887 06 11 A05 29...

Страница 30: ...233887 06 11 A05 30...

Страница 31: ...hef Numatic International Limited Chard Somerset TA20 2GB www numatic co uk DK DICHIARAZIONE DI CONFORMIT EU Con la presente dichiariamo che i seguenti macchinari adempiono a tutte le disposizioni ine...

Страница 32: ...233887 06 11 A05 32...

Отзывы: