Trouble Shooting and Help Guide
TT / TGB 1840
Floor
Care
The 1840 has been designed to scrub and dry a variety of hard floors.
This machine has not been designed to pick up large objects, make sure you pre-sweep the floor before use.
For optimum performance make sure you keep the filters, hoses and floor tool blades clean and free from debris.
Disconnect from the power supply or remove the battery BEFORE commencing maintenance or cleaning of your machine.
After every time the machine is used.
The machine should be left in a clean and tidy state, drain
all fluids, clean all filters, pipes and place the
battery on charge.
It is recommended you strip and
thoroughly clean the machine and its
components regularly.
At least weekly to avoid operating
troubles and machine breakdowns.
Fitting Brush - Floor Tool, Filling Machine, Fill Gauge, Moving
Water Flow Adjustment, Raising the Floor Tool
Draining Top Tank, Draining Bottom Tank, Clean Water Filter
Changing the Floor Tool Blades
Make sure you read and fully
understand your 1840 manual
before using the machine.
PROBLEM
CAUSE
SOLUTION
Machine will not operate.
Missing or blown fuses.
Battery not connected.
Low battery charge.
.
Vacuum will not operate.
Vacuum not turned on.
Poor water pick-up.
Waste-water tank full.
Blocked vacuum hose.
Loose hose.
Basket filter blocked.
Separator filter blocked.
Poor separator seal.
Damaged separator seal.
Damaged vacuum hose.
Damaged floor-tool blades.
Low battery charge.
No brush / Scrub function.
No brushes fitted.
Brush overloaded.
Little or no water flow.
Clean-water tank empty.
Clean-water tank filter blocked.
Incorrect water flow setting.
Machine just ‘stops’ while
operating.
To much load on the brush system.
Blown fuse in battery pack.