Trouble Shooting and Help Guide

TT / TGB 1840

Floor

Care

The 1840 has been designed to scrub and dry a variety of hard floors. 

This machine has not been designed to pick up large objects, make sure you pre-sweep the floor before use.

For optimum performance make sure you keep the filters, hoses and floor tool blades clean and free from debris.

Disconnect from the power supply or remove the battery BEFORE commencing maintenance or cleaning of your machine.

After every time the machine is used.

The machine should be left in a clean and tidy state, drain 

all fluids, clean all filters, pipes and place the 

battery on charge.

It is recommended you strip and 

thoroughly clean the machine and its 

components regularly.

 

At least weekly to avoid operating 

troubles and machine breakdowns.

Fitting Brush - Floor Tool, Filling Machine, Fill Gauge, Moving

Water Flow Adjustment, Raising the Floor Tool

Operating Switches

Draining Top Tank, Draining Bottom Tank, Clean Water Filter

Clean Separator

Changing the Floor Tool Blades

Charging (Cont)

Make sure you read and fully 

understand your 1840 manual 

before using the machine.

PROBLEM

CAUSE

SOLUTION

Machine will not operate.

Missing or blown fuses.

Battery not connected.

Low battery charge.

Replace fuse

.

Connect Battery.

Charge.

Vacuum will not operate.

Vacuum not turned on.

Turn on.

Poor water pick-up.

Waste-water tank full.

Blocked vacuum hose.

Loose hose. 

Basket filter blocked.

Separator filter blocked.

Poor separator seal.

Damaged separator seal.

Damaged vacuum hose.

Damaged floor-tool blades.

Low battery charge.

Empty.

Clean.

Tighten.

Clean.

Clean.

Clean and refit.

Renew.

Renew.

Renew.

Recharge.

No brush / Scrub function.

No brushes fitted.

Brush overloaded.

Check and fit.

Reset.

Little or no water flow.

Clean-water tank empty.

Clean-water tank filter blocked.

Incorrect water flow setting.

Fill.

Clean.

Adjust tap as desired

Machine just ‘stops’ while 

operating.

To much load on the brush system.

Blown fuse in battery pack.

Reset, decrease the brush load.

Replace 40 Amp fuse.

Removing Battery, Fuse, Charging

Содержание FloorCare TGB 1840

Страница 1: ...ining Top Tank Draining Bottom Tank Clean Water Filter Clean Separator Changing the Floor Tool Blades Charging Cont Make sure you read and fully understand your 1840 manual before using the machine PR...

Страница 2: ...clean water tank Fitting the Floor Tool Make sure the inspection cap is in place on the fluid pipe Swing the floor tool carrier to the side of the machine Secure to the carrier using the two knobs fi...

Страница 3: ...near the base of the handle to raise the floor tool and lock in position On Water Flow Adjustment and Raising the Floor Tool Index page Operating Switches To activate the control panel press the Mode...

Страница 4: ...The On Off Switch and triggers are not required in this mode Fig E Press the mode select button to switch this mode off and return to default mode The panel if unused will automatically turn off afte...

Страница 5: ...ank if leaving your machine for a extended period The cap has a rubber seal and might require a spanner to remove Regular Maintenance Located under the clean water inlet is the clean water filter Clea...

Страница 6: ...the machine Fig 1 2 Remove fixing band holding separator in place Fig 3 Lift off the separator The separator has a sealing rubber which should be examined at every clean down Fig 4 Rinse using clean...

Страница 7: ...Fig 1 Refitting the Floor Tool Blades 1 2 3 4 5 Floor Tool Overview 1 Retaining knobs x 4 2 Front blade slotted 3 Blade carrier 4 Rear blade 5 Floor tool main body NOTE The blades are designed to be...

Страница 8: ...t you disconnect the battery from the machine If the machine will be standing unused for a period of 30 days or more then batteries must be fully charged Note Batteries should be recharged every three...

Страница 9: ...es are discharged the battery charge level meter lights will go out from top to bottom If the battery charge level is allowed to discharge to the point that only one red light remains illuminated the...