Unplug the battery from the machine using the red connection handle (Fig.A & B).
The battery can then be lifted from the machine for storage or charging (Fig.C).

C

B

A

Removing the Battery ...

The battery pack comes fitted with a 40 amp safety fuse.
Replace the fuse using (208526) Numatic approved part

Recharge the machine fully after its last use. Do not leave the machine in a discharged state.

Under abnormal use; i.e. leaving the machine without charging for a period of time, we advise that you disconnect the battery from the machine. 

If the machine will be standing unused for a period of 30 days or more, then batteries must be fully charged.

Note:

 Batteries should be recharged every three months. Charge fully the day before you start using the machine again.

Under normal daily usage: 

Recharge batteries after each use regardless of machine operation time. Connect the charger unit to the battery and plug the charger into a suitable power 

supply.

Battery Charging ...

Removing the Battery Pack Fuse ...

Fitting Brush - Floor Tool, Filling Machine, Fill Gauge, Moving

Water Flow Adjustment, Raising the Floor Tool

Operating Switches

Draining Top Tank, Draining Bottom Tank, Clean Water Filter

Clean Separator

Changing the Floor Tool Blades

Charging (Cont)

Removing Battery, Fuse, Charging

Содержание FloorCare TGB 1840

Страница 1: ...ining Top Tank Draining Bottom Tank Clean Water Filter Clean Separator Changing the Floor Tool Blades Charging Cont Make sure you read and fully understand your 1840 manual before using the machine PR...

Страница 2: ...clean water tank Fitting the Floor Tool Make sure the inspection cap is in place on the fluid pipe Swing the floor tool carrier to the side of the machine Secure to the carrier using the two knobs fi...

Страница 3: ...near the base of the handle to raise the floor tool and lock in position On Water Flow Adjustment and Raising the Floor Tool Index page Operating Switches To activate the control panel press the Mode...

Страница 4: ...The On Off Switch and triggers are not required in this mode Fig E Press the mode select button to switch this mode off and return to default mode The panel if unused will automatically turn off afte...

Страница 5: ...ank if leaving your machine for a extended period The cap has a rubber seal and might require a spanner to remove Regular Maintenance Located under the clean water inlet is the clean water filter Clea...

Страница 6: ...the machine Fig 1 2 Remove fixing band holding separator in place Fig 3 Lift off the separator The separator has a sealing rubber which should be examined at every clean down Fig 4 Rinse using clean...

Страница 7: ...Fig 1 Refitting the Floor Tool Blades 1 2 3 4 5 Floor Tool Overview 1 Retaining knobs x 4 2 Front blade slotted 3 Blade carrier 4 Rear blade 5 Floor tool main body NOTE The blades are designed to be...

Страница 8: ...t you disconnect the battery from the machine If the machine will be standing unused for a period of 30 days or more then batteries must be fully charged Note Batteries should be recharged every three...

Страница 9: ...es are discharged the battery charge level meter lights will go out from top to bottom If the battery charge level is allowed to discharge to the point that only one red light remains illuminated the...

Отзывы: