17
5. Disinfection of feeding bottles, teats and accessories
5.1 General information on
disinfecting
Newborn babies do not initially have sufficient
antibodies to be able to protect themselves
from pathogenic germs. For this reason it is vital
that disinfected teats and bottles are used when
preparing infant feeds. Even the most minute
food particles left on teats and feeding bottles
can easily lead to a build-up of bacteria, which is
a health hazard to infants. Components should
therefore also be cleaned each time before dis-
infecting. The steam steriliser uses heat to disin-
fect the components. Water is heated to above
90 °C and is converted into steam. The heat
generated therefore disinfects the components
inside the steriliser swiftly and reliably. This way
the teats and feeding bottles only come into
contact with heat and steam. As the steam ster-
iliser uses very little water, only minimal power
is required too.
5.2 Disinfection
Beware:
All components being disinfected must
be washed thoroughly and be free of any food
residues.
The drawings
A
to
I
for the disinfecting process
can be found on the unfolded page.
1. Remove the measuring jug
9
from the base
6
(Fig.
A
).
2. Using the jug
9
measure 70ml of tap water
and pour into the base
6
(Fig.
A
).
N.B.:
70 ml corresponds to two beakers full
of water (2x 35ml).
3. Place the steam receptacle
5
on the base
6
(Fig.
B
).
4. Place the bottle holder
4
in the steam recep-
tacle (Fig.
C
).
Beware:
Always disinfect the bottles open and
dismantled, otherwise the material can become
misshapen.
5. Place the open bottles in the holder
4
(Fig.
D
).
N.B.:
Stack the lids if possible in the holder
4
. This will save space in the accessories
basket (Fig.
E
).
6. Place the accessories basket
3
on top of the
steam receptacle (Fig.
F
).
7. Lay the accessories in the basket
3
(Fig.
G
).
8. Place the lid
1
on top of the basket
3
(Fig.
H
).
9. Insert the mains plug into a suitable socket.
N.B.:
If the control light
8
is already lit, this
means the On switch
7
has already been
inadvertently activated.
10.Switch the device on using the On switch
7
.
The control light
8
will light up (Fig.
I
).
The steam steriliser will switch off automatically
after disinfecting and the control light will go
out.
Warning!
Directly after switching off, the device
will still contain steam, which will, to
some extent, escape through the
steam outlet valve. You should there-
fore take care not to scald yourself.
Allow the equipment to cool down
while sealed for at least three minutes.
Directly after disinfecting the bottles
will be very hot and should only be
removed using the tongs supplied.
Beware!
The plug should be removed from the
socket after each use to ensure that the device
cannot be inadvertently switched on.
5.3 Please observe the following:
•
The disinfection process lasts approx.
8 minutes using 70 ml of water.
•
Disinfection is only guaranteed if the
process is not interrupted and the time is
not reduced.
Vaporisator 09/08 Seite 17 Dienstag, 7. Oktober 2008 8:17 08
Содержание VAPO RAPID
Страница 3: ...A B C D E F G H I Vaporisator 09 08 Seite 1 Dienstag 7 Oktober 2008 7 54 07 ...
Страница 4: ...4 5 8 10 2 1 3 6 7 9 Vaporisator 09 08 Seite 1 Dienstag 7 Oktober 2008 7 54 07 ...
Страница 5: ...Vaporisator 09 08 Seite 2 Dienstag 7 Oktober 2008 7 54 07 ...
Страница 6: ...Vaporisator 09 08 Seite 2 Dienstag 7 Oktober 2008 7 54 07 ...
Страница 82: ...78 3 5 3 1 3 2 2 1 77 Bedienung RUS Seite 78 Freitag 29 Januar 2010 10 41 10 ...
Страница 83: ...79 70 L M 3 3 3 4 M Bedienung RUS Seite 79 Freitag 29 Januar 2010 10 41 10 ...
Страница 84: ...80 3 5 M 3 6 Bedienung RUS Seite 80 Freitag 29 Januar 2010 10 41 10 ...