9
1.
Make sure the pipes are at the correct centres. A cavity is required
within the depth shown on the diagram. The depth depends on
how far you want the valve protruding from the finished surface.
The dimension is from the finished surfaced.
2.
Remove the handle from the valve and place all components in a
safe place (see section 8 for handle removal). You will need to fix
the valve to a fixing surface within the cavity and fasten the valve
with screws. Flush the pipes through before connecting the valve.
3.
Connect the valve using the compression fittings. Connect the
required outlet.
Check for leaks.
4.
Tile up to the valve so that the Plate will cover the cavity.
Do not
permanently fill the cavity in as this may be required for access
at a later date.
5.
Place the plate over the valve collar and push flush to the wall.
Seal around the plate to prevent water entering the cavity.
Replace the handle.
6.
Calibrate the valve and commission as advised (see section 8 and
11).