20
•
Installation
2.11 Gate Control Configurations
The gate control signals of the independent counters are internally
pulled high hence they are default enable if no external gate used.
When the external gate signals are used, the counters can be used
to measure pulse width. Therefore, the time interval of the counter
gate can be precisely controlled and frequency measurement is
possible. Figure 2.10 shows the jumper setting of gate control of
counter #1~ #10. ( Note: The gate control of counter #11 and #12 are
always enable. )
GATE n( To 8254 )
VCC
GATE n( From 100 pin
SCSI-II Connector )
Figure 2.10 Gate source of counter #1 ~#10
2.12 Counter Outputs
The timer / counter output signals (
COUT n
) of 8254 are controlled by
clock source, gate control and software programming. All the output
of the 12 counters are sent to the 100 pins connector directly, please
see 'Pin assignment' for corresponding signal pin number.
In addition, the output signal may be used as clock source for
cascaded counters, see the above sections. It is possible to
cascaded ten counters by software setting, see 2.8 for reference.
The counters output
COUT12
is also used as internal interrupt
source (refers to 'Interrupt System').