nubeca BA2115 Скачать руководство пользователя страница 8

If select to display the date and time, the current date and time will 

display when turned off. 

12 hours 

system display

 hour display

minute display

second display

date display

 hour display

minute display

second display

date display

24 hours 

system display

Unit Setting

KPa&mmHg

4. To set unit

Then press the “MEM” button to change the current unit. (kPa 

or mmHg) 

Press the “SET” button and return the step 1.

Press the “START/STOP” button to save the current setting 

and turn off.

5. To set user

“mmHg” display

“kPa” display

Adjusting Settings

12

Adjusting Settings

13

Press the “SET” button and the mark of a user will appear 

when turned off or the display function of the date and time 

is ON. Then press the “SET” button again to change the 

current user.

Finally, press the “

START/STOP

” button to confirm user and 

turn off. 

You can stop the setting anytime when you press the “START/STOP” 

button to save the current setting and turn off.

If select to display the date and time, the current date and time will 

display when turned off. 

BA2115

BA2115

Содержание BA2115

Страница 1: ...Model No BA2115 A01 BA2115...

Страница 2: ...ols Use 2 Important Safety Notes 3 K now Your Unit 4 5 IHB Introduction 6 Before Taking A Measurement 7 Quick Reference Guide 8 Battery lnstallation Replacement 9 Adjusting Settings 1 To set year 10 2...

Страница 3: ...sing measured results may be dangerous Follow the instructions of your healthcare provider Operate the unit only as intended Don t use for any other purpose The unit is intended to use in measuring bl...

Страница 4: ...to Air Socket Metal Arm Cuff Warning 1 Do not use rechargeable batteries 2 When using optional AC adapter the AC adapter must comply with the requirements of standard IEC60601 1 3 Optional AC adapter...

Страница 5: ...d bathing for 30 minutes before taking a measurement 2 Stress raises blood pressure Avoid taking measurements during stressful times 3 The cuff can be applied to your left or right wrist Always measur...

Страница 6: ...ve polarities match the polarities of the battery compartment as indicated Remove the battery cover from the battery compartment Replace the battery cover Press the START STOP button All symbols appea...

Страница 7: ...inue with next step Then set the day the time system conversion the hour and the minute by using the same way Continue with step 3 2 To set date and time 10 Press the MEM botton to increase one year P...

Страница 8: ...START STOP button to save the current setting and turn off 5 To set user mmHg display kPa display Adjusting Settings 12 Adjusting Settings 13 Press the SET button and the mark of a user will appear wh...

Страница 9: ...ug is inserted properly in the main unit 1 15 Proper Use of the Arm Cuff 8 Relax your arm keep the palm upward and the fingers curving naturally then turn on the unit and start to measure Wrap the cuf...

Страница 10: ...rts to inflate automatically Press the START STOP button 1 In order to accelerate the measurement time for the systolic pressure more than 180 mmHg press and hold the memory button until the unit infl...

Страница 11: ...before reading the memory To read the average value Press the MEM button The average value symbol will display the average value of the latest 3 times measurement taken Turn to next The 1st latest mea...

Страница 12: ...ower value represents the blood pressure produced by relaxation of the heart muscle Blood Circulation 21 About Blood Pressure Note When a person s systolic and diastolic pressures fall into different...

Страница 13: ...arm and body and keep quiet Error Indicators 22 The following symbol will appear on the display when measuring abnormally 23 Care and Maintenance Do not clean the body and cuff with naphtha thinner or...

Страница 14: ...overvoltage II pollution degree 2 The risk of patient and user can be lowered to acceptable level The unit might not meet its performance specification if stored or used outside the following specifie...

Страница 15: ...lood Pressure Monitor is intended for use in the electromagnetic environment specified below The customer or the user of Digital Blood Pressure Monitor should assure that it is used in such an environ...

Страница 16: ...e does not cover damage incurred by use of the unit not in accordance with the instructions accidental damage or being tampered with or serviced by unauthorized service agents 29 28 EMC Table Recommen...

Отзывы: