The unit, excluding the unit cuff, is guaranteed to be free of defects in 
workmanship and materials  for a period of two years from the date listed
 on the purchase record. when used in accordance with the instructions 
provided with the unit. The unit cuff is warranted to be free from detects in 
materials and workmanship appearing within one year from the date listed
 on the purchase record when the unit is used in accordance with the
 instructions provided with the unit.

For repair under this warranty. Our authorized service agent must be
 advised of the fault within the period of the warranty. This warranty covers
 parts and labor only under normal operations. A transportation fee or
 freight fee that may be incurred will be the owner's responsibility. Any 
defect resulting from natural causes, e.g., flood, hurricane etc., is not within 
this guarantee. This guaranty does not cover damage incurred by: use of 
the unit not in accordance with the instructions, accidental damage, or
 being tampered with or serviced by unauthorized service agents. 

Unit subjected to misuse, abuse, and neglect of these manual content, 
non-instructional purposes; unauthorized repair or modifications will be
 excluded from this warranty. This guarantee specifically excludes 
expendables and consumables, for example batteries. All warranty claims 
must be directed to the distributor responsible for the sale of the device. 
The content of this warranty is subject to change without further notice.

Periodical check:  
Sensitive measuring devices must be checked from time to time for 
accuracy and leakage, we therefore recommend that the performance 
should be checked every 2 years.
Check and maintenance and repair for the unit, please contact the local 
distributor for details.

Clean the cuff with a soft dry cloth.

The unit satisfies the requirements of EN60601-1

Medical electrical 

equipment Part 1: General requirements for basic safety and essential 

performance; EN60601-1-2: Medical electrical equipment Part 1-2: 

General requirements for basic safety and essential performance – 

Collateral standard: Electromagnetic compatibility – Requirements and 

tests; EN1060-1: Non-invasive sphygmomanometers – Part 1: General 

Warranty Information

Federal law restricts this device to sale by or on the order of a physician.

27

requirements;  EN1060-3: Non-invasive sphygmomanometers – Part 3: 

Supplementary requirements for electro-mechanical blood pressure 

measuring system. EN1060-4

Non-invasive sphygmomanometers – 

Part 4: Test procedures to determine the overall system accuracy of 

automated non-invasive sphygmomanometers.

Warranty Information

Warning: Do not use Luer lock connector in the construction tubing, There 

is a possibility that  they might be inadvertently connected to intravascular 

fluid systems, allowing air to be pumped into a blood vessel.

It can’t be used while the wrist (arm) has bleeding or wound to avoid the 

blood flowing from the wound in pressurizing.

Protection Class: Internally powered equipment 

Applied Part Type: Type B

Moisture Protection: IPX0, continue operation

Applied parts contains cuff.

The device

accessories and the packaging have to be disposed of waste 

correctly at the end of the usage. Please follow Local Ordinances or 

Regulations for disposal.

WARNING: No modification of this equipment is allowed.

Manufacturer will make available on request circuit diagrams, component 

part lists etc for the service personnel in parts repair.

Caution: this machine should not be used adjacent to or stacked with other 
equipment and that if adjacent or stacked use is necessary, this machine 
should be observed to verify normal operation in the configuration in which 
it will be used.

*MEDICAL ELECTRICAL EQUIPMENT needs special precautions 
regarding EMC and needs to be installed and put into service according to 
the EMC information provided in the ACCOMPANYING DOCUMENTS.
*Portable and mobile RF communications equipment can affect MEDICAL 
ELECTRICAL EQUIPMENT.
* Do not use a mobile phone or other devices that emit electromagnetic 
fields, near the unit. This may result in incorrect operation of the unit.

Содержание BA2015

Страница 1: ...Model No BA2219 A00...

Страница 2: ...3 Konw Your Unit 4 5 IHB Introduction 6 Before Taking A Measurement 7 Quick Reference Guide 8 Battery lnstallation Replacement 9 Adjusting Settings 1 To set year 10 2 To set date and time 10 11 3 To...

Страница 3: ...or moderate injury to the user or patient or damage to the equipment or other property Read all information in the instruction manual and any other literature included in the box before using the uni...

Страница 4: ...Hose Air Plug Insert to Air Socket Metal Arm Cuff Warning 1 Do not use rechargeable batteries 2 When using optional AC adapter the AC adapter must comply with the requirements of standard IEC60601 1 3...

Страница 5: ...d bathing for 30 minutes before taking a measurement 2 Stress raises blood pressure Avoid taking measurements during stressful times 3 The cuff can be applied to your left or right wrist Always measur...

Страница 6: ...ative polarities match the polarities of the battery compartment as indicated Remove the battery cover from the battery compartment Replace the battery cover Press the START STOP button All symbols ap...

Страница 7: ...the month and press the SET button and continue with next step Then set the day the time system conversion the hour and the minute by using the same way Continue with step 3 2 To set date and time 10...

Страница 8: ...the START STOP button to confirm user and turn off You can stop the setting anytime when you press the START STOP button to save the current setting and turn off If select to display the date and time...

Страница 9: ...plug is inserted properly in the main unit 1 15 Proper Use of the Arm Cuff 8 Relax your arm keep the palm upward and the fingers curving naturally then turn on the unit and start to measure Wrap the...

Страница 10: ...uff starts to inflate automatically Press the START STOP button 1 In order to accelerate the measurement time for the systolic pressure more than 180 mmHg press and hold the memory button until the un...

Страница 11: ...memory To read the average value Press the button The average value symbol will display the average value of the latest 3 times measurement taken Turn to next The 1st latest measurement value The 2nd...

Страница 12: ...nts the blood pressure produced by relaxation of the heart muscle Blood Circulation 21 About Blood Pressure Note When a person s systolic and diastolic pressures fall into different categories the hig...

Страница 13: ...ve your arm and body and keep quiet Error Indicators 22 The following symbol will appear on the display when measuring abnormally 23 Care and Maintenance Do not clean the body and cuff with naphtha th...

Страница 14: ...y using the oscillometric method The unit is intended for usingin only adult population not applied to the other populations such as neonatal baby It can t be used while the wirst arm has bleeding or...

Страница 15: ...60601 1 2 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance Collateral standard Electromagnetic compatibility Requirements and tests EN1060 1 Non in...

Страница 16: ...1000 4 8 6 kV contact 8 kV air 6 kV contact 8 kV air 3A m 3A m Floors should be wood concrete or ceramic tile If floor are covered with synthetic material the relative humidity should be at least 30 P...

Страница 17: ...be necessary such as reorienting or relocating the Digital Blood Pressure Monitor Radiated RF IEC 61000 4 3 IEC 60601 test Compliance level level Electromagnetic environment guidance Recommended sepa...

Отзывы: