About Blood Pressure

Lower pressure

Relaxation of the 

heart muscle

Pressure decreased 

to the blood vessel

Blood return heart

Higher pressure

Contraction of 

the heart muscle

Pressure increased 

to the blood vessel

Extrude blood

Systolic Blood Pressure

Diastolic Blood Pressure

The blood circulation is responsible for supplying the body with oxygen. 
Blood pressure is the pressure exerted on the arteries.

The systolic blood pressure value (higher pressure or top value) represents 
the blood pressure produced by contraction of the heart muscle.

The diastolic blood pressure value (lower pressure or lower value) represents 
the blood pressure produced by relaxation of the heart muscle.

Blood Circulation

21

About Blood Pressure

*Note!

When a person’s systolic and diastolic pressures fall into different categories, 
the higher category should apply.

WHO

Red

Yellow

Green

80

85

90

100

110

Diastolic Blood Pressur (mmHg)

120

130

140

160

180

Systolic Blood Pressure (mmHg)

Optimal

blood pressure

(target value)

Normal blood pressure

Normal systolic value

Mild hypertension

Moderate hypertension

Severe hypertension

After each measurement is completed, the LCD display will show your 
position automatically on the six segments of the bar indicator which 
corresponds to World Health Organization (WHO) Blood Pressure Indicator.

Reference Material: Journal of Hypertension 1999, Vol 17 No.2

Classification of Blood Pressure

Classification of Blood Pressure

Содержание BA2015

Страница 1: ...Model No BA2219 A00...

Страница 2: ...3 Konw Your Unit 4 5 IHB Introduction 6 Before Taking A Measurement 7 Quick Reference Guide 8 Battery lnstallation Replacement 9 Adjusting Settings 1 To set year 10 2 To set date and time 10 11 3 To...

Страница 3: ...or moderate injury to the user or patient or damage to the equipment or other property Read all information in the instruction manual and any other literature included in the box before using the uni...

Страница 4: ...Hose Air Plug Insert to Air Socket Metal Arm Cuff Warning 1 Do not use rechargeable batteries 2 When using optional AC adapter the AC adapter must comply with the requirements of standard IEC60601 1 3...

Страница 5: ...d bathing for 30 minutes before taking a measurement 2 Stress raises blood pressure Avoid taking measurements during stressful times 3 The cuff can be applied to your left or right wrist Always measur...

Страница 6: ...ative polarities match the polarities of the battery compartment as indicated Remove the battery cover from the battery compartment Replace the battery cover Press the START STOP button All symbols ap...

Страница 7: ...the month and press the SET button and continue with next step Then set the day the time system conversion the hour and the minute by using the same way Continue with step 3 2 To set date and time 10...

Страница 8: ...the START STOP button to confirm user and turn off You can stop the setting anytime when you press the START STOP button to save the current setting and turn off If select to display the date and time...

Страница 9: ...plug is inserted properly in the main unit 1 15 Proper Use of the Arm Cuff 8 Relax your arm keep the palm upward and the fingers curving naturally then turn on the unit and start to measure Wrap the...

Страница 10: ...uff starts to inflate automatically Press the START STOP button 1 In order to accelerate the measurement time for the systolic pressure more than 180 mmHg press and hold the memory button until the un...

Страница 11: ...memory To read the average value Press the button The average value symbol will display the average value of the latest 3 times measurement taken Turn to next The 1st latest measurement value The 2nd...

Страница 12: ...nts the blood pressure produced by relaxation of the heart muscle Blood Circulation 21 About Blood Pressure Note When a person s systolic and diastolic pressures fall into different categories the hig...

Страница 13: ...ve your arm and body and keep quiet Error Indicators 22 The following symbol will appear on the display when measuring abnormally 23 Care and Maintenance Do not clean the body and cuff with naphtha th...

Страница 14: ...y using the oscillometric method The unit is intended for usingin only adult population not applied to the other populations such as neonatal baby It can t be used while the wirst arm has bleeding or...

Страница 15: ...60601 1 2 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance Collateral standard Electromagnetic compatibility Requirements and tests EN1060 1 Non in...

Страница 16: ...1000 4 8 6 kV contact 8 kV air 6 kV contact 8 kV air 3A m 3A m Floors should be wood concrete or ceramic tile If floor are covered with synthetic material the relative humidity should be at least 30 P...

Страница 17: ...be necessary such as reorienting or relocating the Digital Blood Pressure Monitor Radiated RF IEC 61000 4 3 IEC 60601 test Compliance level level Electromagnetic environment guidance Recommended sepa...

Отзывы: