background image

General                                      Electrical                    

Weight

3 Phase (400V) ONLY

(kg)

(nominal)

Unit

Speed

Power

f lc sc 

Code

pm

(kw)

(amps)

(amps)

QTR*C 1-3*

820

2.2

5.4

27.0

168.7

QTR*C 2-3*

925

2.2

5.4

27.0

168.7

QTR*C 3-3*

925

3.0

6.9

38.0

174.6

QTR*C 4-3*

1040

1.5

3.7

18.5

159.6

QTR*C 5-3*

1040

2.2

5.4

27.0

168.7

QTR*C 6-3*

1040

3.0

6.9

38.0

174.6

QTR*C 7-3*

1040

4.0

10.0

60.0

193.6

QTR*C 8-3*

1160

2.2

5.4

27.0

168.7

QTR*C 9-3*

1160

3.0

6.9

38.0

174.6

QTR*C 10-3*

1160

4.0

10.0

60.0

193.6

QTR*C 11-3*

1160

5.5

12.0

75.0

231.6

QTR*C 13-3*

1260

3.0

6.9

38.0

174.6

QTR*C 14-3*

1260

4.0

10.0

60.0

193.6

QTR*C 15-3*

1260

5.5

12.0

75.0

231.6

QTR*C 16-3*

1360

3.0

6.9

38.0

174.6

QTR*C 17-3*

1360

4.0

10.0

60.0

193.6

QTR*C 18-3*

1360

5.5

12.0

75.0

231.6

QTR*C 19-3*

1440

3.0

6.9

38.0

174.6

QTR*C 20-3*

1440

4.0

10.0

60.0

193.6

QTR*C 21-3*

1440

5.5

12.0

75.0

231.6

General

Electrical

Weight

3 Phase (400V) ONLY

(kg)

(nominal)

Unit

Speed

Power

flc             sc

Code

rpm

(kw)

(amps)

(amps)

QTR*B 1-3*

875

1.1

2.9

13.0              116

QTR*B 2-3*

1005

1.1

2.9

13.0

116

QTR*B 3-3*

1005

1.5

3.7

18.5

125

QTR*B 4-3*

1085

1.1

2.9

13.0

116

QTR*B 5-3*

1085

1.5

3.7

18.5

125

QTR*B 6-3*

1165

0.75

2.1

9.5

113

QTR*B 7-3*

1165

1.1

2.9

13.0

116

QTR*B 8-3*

1165

1.5

3.7

18.5

125

QTR*B 9-3*

1165

2.2

5.4

27.0

134

QTR*B 10-3*

1225

1.1

2.9

13.0

116

QTR*B 11-3*

1225

1.5

3.7

18.5

125

QTE*B 12-3*

1225

2.2

5.4

27.0

134

QTR*B 13-3*

1225

3.0

6.9

38.0

140

QTR  Roof Mounted Belt Drive 
Twinfans  (continued)

Table  5.   Start & Run currents etc.

CASE SIZE ‘B’

Table  6.   Start & Run currents etc.

CASE SIZE ‘C’

Installation and Maintenance    

QUIETWIN  QTR BELT DRIVE TWINFAN

4

General

Electrical

Weight

3 Phase (400v) ONLY               kg

(nominal)

Unit

Speed

Power

f lc             sc

Code

rpm

(kw)

(amps)

(amps)

QTR*D 1-3*

700

1.5              3.7           18.5           682

QTR*D 2-3*

700

2.2              5.4           27.0           691

QTR*D 3-3*

700

3.0              6.9          38..0           697

QTR*D 4-3*

700

4.0           10.0           60.0           716

QTR*D 5-3*

700

5.5           12.0           75.0           730

QTR*D 6-3*                   700         7.5

16.0           98.0

750

QTR*D 7-3*                   800          1.5

3.7

18.5

682

QTR*D 8-3*                   800          2.2

5.4

27.0

691

QTR*D 9-3*                   800          3.0             6.9        38.0  

697

QTR*D 10-3*

800

4.0

10.0

60.0

716 

QTR*D 11-3*

800

5.5

12.0

75.0

730

QTR*D 12-3*

800

7.5

16.0

98.0

750

QTR*D 13-3*

800

11.0

23.0

154.0

794

QTR*D 14-3*

900

3.0

6.9

38.0

697

QTR*D 15-3*

900

4.0

10.0

60.0

716

QTR*D 16-3*

900

5.5

12.0

75.0

730

QTR*D 17-3*

900

7.5

16.0

98.0

750

QTR*D 18-3*

900

11.0

23.0

154.0

794

QTR* D 19-3*

900

15.0

30.0

225.0

824

QTR*D 20-3*

1000

4.0

10.0

60.0

716

QTR*D 21-3*

1000

5.5

12.0

75.0

730

QTR*D 22-3*

1000

7.5

16.0

98.0

750

QTR*D 23-3*

1000

11.0

23.0

154.0

794

QTR*D 24-3*

1000 15.0

30.0

225.0

824

QTR*D 25-3*

1000

18.5

38.0

266.0

910

QTR*D 26-3*

1100

5.5

12.0

75.0

730

QTR*D 27-3*

1100

7.5

16.0

98.0

750

QTR*D 28-3*

1100

11.0

23.0

154.0

794

QTR*D 29-3*

1100

15.0

30.0

225.0

824

QTR*D 30-3*

1100

18.5

38.0

266.0

910

QTR*D 31-3*

1100

22.0

44.0

308.0

940

QTR*D 32-3*

1200

7.5

16.0

98.0

750

QTR*D 34-3*

1200

15.0

30.0

225.0

824

QTR*D 35-3*

1200

18.5

38.0

266.0

910

QTR*D 36-3*

1200

22.0

44.0

308.0

940

QTR*D 37-3*

1200

30.0

59.0

413.0

1030

Table  7.   Start & Run currents etc.

CASE SIZE ‘D’

Содержание QUIETWIN QTR

Страница 1: ...ames are supported on the base by resilient mountings allowing the fan unit to be operated with out the need for separate anti vibration fan case mountings The units incorporate two independent motors...

Страница 2: ...he installer the lower edge of the casing has an internal skirt allowing the unit to be located on an upstand or prefabricated curb if desired See prefabricated curb details on page 5 The unit should...

Страница 3: ...23 3 1400 1 5 3 7 18 5 96 4 CASE SIZE A Table 4 Start Run currents etc Electrical Details See table 3 4 5 Because the run and start currents depend upon the duty and asso ciated ductwork of an individ...

Страница 4: ...t Drive Twinfans continued Table 5 Start Run currents etc CASE SIZE B Table 6 Start Run currents etc CASE SIZE C Installation and Maintenance QUIETWIN QTR BELT DRIVE TWINFAN 4 General Electrical Weigh...

Страница 5: ...nit Support Base Removable top covers Unit support base Inlet spigot 2500 2315 200 1200 1200 200 min100 min 75 50 1790 2490 Unit Weight and Fixing Size D units For unit weights see electrical informat...

Страница 6: ...power control Figure 9b 6 3 YEAR WARRANTY The three year warranty starts from the date of delivery and includes parts and labour for the first year The labour element is subject to full free and safe...

Страница 7: ...the User Control is included inside the fan unit for delivery to site Take care not to misplace the item before installation Wiring Connections Supply 230V 1 Phase to terminals E N L in control module...

Страница 8: ...K Y RUN FAULT Low voltage Communications Cable Not used in this option MT AVI connection BL RD BK Y MICROSAVE USER CONTROL CONTROL MODULE IN FAN Single phase QUIETWIN with MICROSAVE control Link Link...

Страница 9: ...S Building Management System override control on off and system status Code Description CT A Auto duty sharing CT M Manual duty sharing Mains Control Options NOTE See relevant Installation Maintenance...

Страница 10: ...1 L2 N E H BL RD BK Y RUN FAULT 230v MAINS CONTROL 230v 1 phase supply Link Link NET CT AVI Audible Visual Indicator connection QUIETWIN FAN Three phase 230v Switched Live Connection twinfan operates...

Страница 11: ...es operate freely by locating the spindle and flap through the blower outlet aperture and carefully moving the flap A click will be heard when the switch operates See fig 11 NOTE Do not bend the flaps...

Страница 12: ...g switches operate freely by locating the spindle and flap through the blower outlet aperture and carefully moving the flap A click will be heard when the switch oper ates See fig 14 NOTE Do not bend...

Страница 13: ...30364 530373 530368 530372 530367 530373 530368 530372 530367 530373 530368 530374 530369 530373 530368 530374 530369 530375 530373 530368 530374 530375 530376 530374 530369 530375 530376 530374 53036...

Страница 14: ...e Directive Applied Harmonised Standards E50081 1 EN50082 1 EN60204 1 EN60335 2 80 Basis of Self Attestation Quality Assurance to BS EN ISO 9001 BSI Registered Firm Certificate No FM 149 Signature of...

Страница 15: ...37 EC Machinery Directive 93 44 EEC Amendment to the Machinery Directive Applied Harmonised Standards EN292 1 EN292 2 EN294 EN29001 Applied National Standards BS848 Parts One Two and Five Signature o...

Страница 16: ...tion 4 2 Where installation accessories are supplied with the specified equipment eg wall mounting brackets They are to be used to support the equipment only Other system components must have separate...

Отзывы: