3.2 Installation (First Fix)

3.2.1 MRXBOX-FF2

The First Fix plenum chamber should be fixed (fixings supplied by 
others) with the off centre cylindrical cut-outs nearest to the wall the 
MVHR unit is to be installed on. A 30mm clearance between the wall 
and the rear face of the plenum chamber is required (Figures 1 and 10).

The ceiling of the property will require an appropriate size cut out to 
allow the connection to be made when the secondary items are to be 
fitted.

3.3 Installation

3.3.1 MRXBOX-SIL2

The unit is designed for mounting on a solid wall, a gypsum block or 
stud/plasterboard wall will not suffice. If fixing to a stud wall a piece 
of MDF at least 25mm thick should be solidly fixed behind the board, 
the MDF panel should ideally run from floor to ceiling but must be a 
minimum of 2m. The MDF panel should also extend width wise over a 
minimum of three studs with centres no more than 400mm, additional 
vertical supports may be required.

For more detailed information on how to mount the unit and structural 
requirements please refer to the I&M document supplied with the 
MVHR unit. 

Please note 

that a clear working space is required around the installed 

MVHR unit to allow the cover to be removed and provide sufficient 
access for maintenance such as a filter change. Please allow a minimum 
of 430mm in front of the unit (continued overleaf).

The below information regarding the angle brackets is only 
relevant when the installation includes both a MRXBOX-SIL2 and 
MRXBOX-FF2, if this is not the case the MVHR unit should be fitted 
using the standard installation instructions supplied with that 
product. If only fitting an MRXBOX-SIL2 this should then be sat on 
top of the MVHR unit and clamped in place as detailed later in this 
section.

If fitting in conjunction with a MRXBOX-AV2 follow the installation 
instructions with that product.  A MRXBOX-AV2 cannot be used if 
fitting both a MRXBOX-SIL2 and MRXBOX-FF2.

The wall mounting brackets and angle bracket (7713046) should now 
be fitted (fixings supplied by others) according to the installed position 
of the plenum and the measurements shown in Figure 9.

MRXBOX-SIL2 to be hung on the wall using mounting bracket supplied 
loose in the MVHR unit packaging, see below.

The MVHR unit can then be sat on the angle brackets and the cross 
brace should be fitted using the M5 fixings provided, once the unit is in 
position.

Adjustable Foot

Angle Bracket

Locking Nut

Raise the units using the adjustment feet provided until the  
MRXBOX-SIL2 is lifted off its wall mounting bracket, ensuring the two 
sections are correctly aligned and fasten the toggle clamps on the 
sides of the units. The safety pins supplied should be fitted to secure 
the clamps in place (Figure 7). Continue to raise the units using the 
adjustment feet again checking for good alignment to form a seal 
against the MRXBOX-FF2 and ensure installation is level.

When positioning is complete the adjustment feet should be secured in 
position using the four locking nuts (Figure 8).

Please note

 the above method is the preferred installation 

arrangement, a minimum gap of 75mm either side of the unit is advised 
to allow access to the toggle clamps.

If space constraints do not allow this, the toggle clamps can be replaced 
with the metal fixing plates provided (Figure 9). The MVHR unit and 
MRXBOX-SIL2 will need to be secured together and lifted as one 
assembly using suitable lifting equipment.

Содержание MRXBOX-SIL2

Страница 1: ...t Protective Steel Toed Shoes when handling heavy objects Full Finger Gloves Marigold PU800 or equivalent when handling sheet metal components Semi Fingerless Gloves Marigold PU3000 3DO or equivalent...

Страница 2: ...ing length of self adhesive seal to the top surface of the MRXBOX SIL2 to form a sealed perimeter around each circular cut out Figure 3 Ensure all joins are mated neatly to prevent leakage 2 3 MVHR Un...

Страница 3: ...and MRXBOX FF2 if this is not the case the MVHR unit should be fitted using the standard installation instructions supplied with that product If only fitting an MRXBOX SIL2 this should then be sat on...

Страница 4: ...9 2 6 4 4 3 8 7 6 1 6 6 Adjustable Feet 626 Wall Suitable structure Side view 445 605 417 CRS 353 172 CRS Top view 670 110 489 Side view 220 172 CRS 97 400 Face to be mounted nearest to wall 242 CRS...

Страница 5: ...led EPP plastic ducting nylon corner pieces plastic heat exchangers packaging material and other plastic components can be segregated into mixed plastic and widely recycled Cardboard packaging wood us...

Страница 6: ...6 20 07 20 Document Number 671802 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOX SIL2 MRXBOX FF2 Installation Manual NOTES...

Страница 7: ...7 20 07 20 Document Number 671802 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOX SIL2 MRXBOX FF2 Installation Manual NOTES...

Страница 8: ...8 20 07 20 Document Number 671802 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOX SIL2 MRXBOX FF2 Installation Manual NOTES...

Отзывы: