8.0 CONNECTION & WIRING DIAGRAMS
8.1 Connection Diagram & Wiring Diagram Reference Tables
CODE DESCRIPTION:
B 8 15 H / E R / CO - L
| | | | | | | |
1 2 3 4 5 6 7 8
1. BOXER Package Solution Range
2. ERP year:
8 = 2018
3. Unit Size:
05, 10, 15 and 20
4. Heat
Exchanger:
H = Horizontal Plate
5. Heater:
L = LPHW
E = Electric
N = No Heating
6. Cooling:
R = Reverse Cycle**
X = DX*
C = Chilled Water
N = No Cooling
7. Control type:
AT = Ecosmart Adapt (Trend)
CO = Ecosmart Connect
ES = Ecosmart Classic
BC = Basic control
8. Handing:
L = Left, R = Right
*Condenser Unit and control by others.
**Ecosmart Connect & Adapt models only.
A series of basic connection and internal wiring diagrams have been provided to
assist on-site wiring. In order to reference the relevant diagrams please use the
code breakdown opposite to determine:
•
Unit size
•
If an electric heater is present
•
If reverse cycle or DX cooling is present
The below tables can then be used to reference the required connection and
wiring diagrams.
Example:
Unit onsite has code
B815H/ER/CO-L.
This indicates a size 15 unit with
electric heating and reverse cycle cooling. Section 9.4 and 9.13 include the basic
connection diagram and wiring diagram respectively.
B8 15 H/ E R /CO-L
Size 15
Electric Heating
Reverse Cycle Cooling
BPS EcoSmart Connect - Internal Wiring Diagram Reference Table
BPS EcoSmart Connect- Basic Connection Diagram Reference Table
Cable glands situated on the sides of the units
Unit Size
Unit Does Not Contain Reverse Cycle DX
Unit Contains Reverse Cycle DX
05
see section 8.2
see section 8.3
10
see section 8.2
see section 8.3
15
see section 8.2
see section 8.4
20
see section 8.2
see section 8.4
Unit Size
Unit DOES NOT Contain
Electric Heater or Reverse
Cycle DX
Unit Contains Electric
Heater
Unit Contains Reverse Cycle
or DX
Unit Contains Electric
Heater & Reverse Cycle or
DX
05
see section 8.5
see section 8.6
see section 8.7
see section 8.9
10
see section 8.5
see section 8.6
see section 8.7
see section 8.9
15
see section 8.5
see section 8.6
see section 8.8
see section 8.10
20
see section 8.5
see section 8.6
see section 8.8
see section 8.10
Содержание ecosmart CONNECT BPS
Страница 19: ...05 11 20 Leaflet Number 671828 BOXER BPS ECOSMART CONNECT CONTROL CO 19...
Страница 21: ...05 11 20 Leaflet Number 671828 BOXER BPS ECOSMART CONNECT CONTROL CO 21...
Страница 25: ...05 11 20 Leaflet Number 671828 BOXER BPS ECOSMART CONNECT CONTROL CO 25...
Страница 33: ...05 11 20 Leaflet Number 671828 BOXER BPS ECOSMART CONNECT CONTROL CO 33...
Страница 45: ...05 11 20 Leaflet Number 671828 BOXER BPS ECOSMART CONNECT CONTROL CO 45...
Страница 55: ...05 11 20 Leaflet Number 671828 BOXER BPS ECOSMART CONNECT CONTROL CO 55 NOTES...