background image

 

RM/RA SERIES OWNER'S MANUAL 

 

 

NUVU® 

MENOMINEE, MICHIGAN 49858 

page 

8

 

SALES FAX (906) 863-5889 • SERVICE FAX (906) 863-6322 

(906) 863-4401 

RECEIPT: 

It  is  essential  to  inspect the unit immediately when it arrives. NUVU® has placed instructions on 
the  packaging  to  help  avoid  damage  in  transit.  However,  accidents  or  negligent  handling  can 
produce hidden damage. These steps should be followed: 
 

A.  Inspect  the  entire  perimeter  of  the  package  for  damage  or  punctures  to  the  packing 

material.  This  may  indicate  damage to the unit inside. Call any and all packing damage 
to the attention of the delivery person. 

 

B.  If  any  packing  damage  is  found  uncrate  the  unit  immediately 

in  the  presence  of  the 

delivery person

 to determine if the unit is damaged. If any damage is found indicate the 

type and amount of damage on the shipping documents and notify NUVU® at (906) 863-
4401 immediately after filing a freight claim. 

 

C.  Uncrate  the  unit  carefully  and  check  the  entire  unit  (top,  sides,  front  and  back)  for  any 

visible or hidden damage. 

 

D.  Remove the unit from the shipping pallet and inspect the bottom for any damage. 

 

E.  If  any  damage  is  noted  after  the  driver  leaves  immediately  contact  the  freight  company 

and NUVU® Food Service Systems. 

 

F.  Check  the  Door(s).  Make  sure  each  Door  closes  completely,  and  that  the  Door  Gasket 

seals  firmly  (refer  to  the 

DOOR  TEST  PROCEDURE

  under 

DOOR  LATCH,  How  to 

Adjust

  in  the 

SERVICE  AND  REPLACEMENT  GUIDE

).  If  it  does  not  close  and  seal 

properly please contact the TOASTMASTER® Service Department for instructions and 
assistance in any required adjustments. 

INSTALLATION PROCEDURES: 

NUVU®  recommends  that  your  RM/RA  series  model  be  installed  by  a  licensed  professional  to 
ensure  proper  positioning  and  connections.  Failure  to  install  your  RM/RA  series  model  properly 
may void your product warranty. 

Position the unit where it will be operated, allowing adequate clearances around the unit for proper 
cooling  and operation. NUVU® recommends a minimum clearance of 4" at the back and on each 
side of the Oven. Make sure the unit sits level and solid. Adjust or shim the Casters or Oven base 
as necessary. 

Check  to  determine  that  the  power  source  is  the  same  voltage  and  phase  as  that  indicated  on  the 
label  on  the  side  of  the  unit.  If  the  voltage  and/or  phase  is  not  the  same  call  NUVU®  service 
department. 

 

 
 
 
 

IMPORTANT: DO NOT ATTACH UNIT IF THE POWER SOURCE DOES NOT 
COINCIDE WITH THE UNIT LABEL!!!  

Содержание RA-4T

Страница 1: ...For NU VU Models RM 4T RM 5T RA 4T RA 5T OWNER S MANUAL NU VU 5600 13th STREET MENOMINEE MICHIGAN 49858 1029 906 863 4401 FAX 906 863 5889 November 2009 ...

Страница 2: ......

Страница 3: ...TENTS ABOUT YOUR NUVU EQUIPMENT 1 WARRANTY 5 RECEIPT AND INSTALLATION 8 START UP 11 OPERATING INSTRUCTIONS 12 MAINTENANCE AND CLEANING GUIDE 14 SERVICE AND REPLACEMENT GUIDE 16 REPLACEMENT PARTS LIST 16 ELECTRICAL SCHEMATICS 18 ...

Страница 4: ......

Страница 5: ...ion long life components superior performance multiple use operation and amplified operating procedures to produce the finest equipment available This means the end user has the best of ALL worlds One of the previous problems of circulating air ovens was the inability to bake dough products evenly without turning the pans or taking the pans out of the oven at different times In the standard convec...

Страница 6: ...rs in tracing shipments to speed delivery and minimize handling NVUV employs the latest accepted packaging standards to ensure that your equipment arrives in excellent condition However damage may still occur due to accident or mishandling by the freight company For this reason it is necessary for the receiving party to immediately do a thorough inspection of the equipment when it arrives NVUV RM ...

Страница 7: ...his limited warranty covers certain electrical electronic and mechanical parts for the time periods described above with the exception of those items detailed under Warranty Limitations Customers who maintain an open account may purchase against their account MasterCard Visa and American Express credit cards are also accepted The return of defective parts is required The return of a defective part...

Страница 8: ...hone The Service Department is available for assistance Monday through Friday from 7 00 a m to 5 30 p m Central Standard Time Additional time for problem solving will not be allowed unless this procedure is followed An appointment for servicing a unit should be set up since time will not be allowed for waiting to service a unit Unless the service person justifies extra time for performing the work...

Страница 9: ...ust be installed and maintained in accordance with NUVU instructions Users are responsible for the suitability of the units or parts to their application There is no warranty against damage resulting from accident abuse alteration misapplication inadequate storage prior to installation or improper specification or other operating conditions beyond our control Claims against carrier s damage in tra...

Страница 10: ...f any damage is noted after the driver leaves immediately contact the freight company and NUVU Food Service Systems F Check the Door s Make sure each Door closes completely and that the Door Gasket seals firmly refer to the DOOR TEST PROCEDURE under DOOR LATCH How to Adjust in the SERVICE AND REPLACEMENT GUIDE If it does not close and seal properly please contact the TOASTMASTER Service Department...

Страница 11: ...qualified installer or electrician should remove the Top Panel of the unit to expose the power terminal connections A copy of the unit wiring schematic is attached to the inside of the unit near the power terminal connections 2 Electrical Connections IMPORTANT ALL POWER SHOULD BE TURNED OFF AT THE WALL BREAKER WHILE THE UNIT IS BEING CONNECTED ...

Страница 12: ...T coincide with the unit requirements you must call the NU VU Service Department F Replace the Top Panel on the unit Be careful not to pull or pinch any wires while installing the panel G Complete the installation of the optional water supply to the unit refer to INSTALLATION OF WATER SUPPLY immediately following H Push the unit back into place Make sure the unit is level and solid INSTALLATION OF...

Страница 13: ... DO NOT OVER TIGHTEN If the joint leaks when tested and further gentle tightening does not stop the leak the two part compression fitting must be replaced Careful attention to these simple procedures will help to ensure an installation without leaks If you have any questions or problems please call the NUVU Service Department at 906 863 4401 INITIAL START UP STANDARD OVEN A Unscrew the glass Light...

Страница 14: ...ped for the desired air flow and the Oven Power Switch to the ON position Determine the recommended temperature for the product to be baked and set your Temperature Control accordingly When the desired temperature is reached approximately 15 20 minutes after start up the Oven Temperature Control Indicator Light will go out NOTE At the beginning of each day you may want to pre heat your Oven 25 hig...

Страница 15: ... original temperature if necessary COOK N HOLD OPTION The COOK N HOLD OPTION allows you to cook a product at one temperature and to hold that product at a lower temperature The 24 Hour Timer along with both the Temperature Control and Hold Control must be set in order for you to utilize the COOK N HOLD option features of your NU VU Oven The Oven Temperature Control must be set at the desired initi...

Страница 16: ...gh cleaning on a regular basis CLEANING Your RM RA series model should be cleaned daily or as soon as possible after a spill has occurred It is essential to maintain a clean unit especially if the public views the unit in your place of business The following general guidelines should be used for cleaning OVEN The Oven Door glass may be cleaned with any good glass cleaning formula The two panes of ...

Страница 17: ...nd that the Element Cover is pushed all the way back and up for a tight fit Secure it in place with the thumbscrews The Oven Sidewalls should be removed on an as needed basis for interior cleaning and mineral removal Replace them the same way as the Element Cover small back lip in the support strip tight to the sides and all the way back EXTERIOR All exterior glass may be cleaned with any good gla...

Страница 18: ... for servicing DO NOT allow any Access Panels to drop When work on the component is finished replace the Panel with care making sure that all wires are properly placed and not pulled or pinched If more than one component is being worked on try to remove only one component at a time REPLACEMENT PARTS LIST RM RA SERIES Reference Description Replacement Part ELECTRICAL COMPONENTS 1 Power Terminal Blo...

Страница 19: ...0 1392 RA SERIES COMPONENTS 18 Solid state relay 66 2003 19 Power supply 50 0947 20 Temperature control sensor 66 1038 21 PLC 66 1152 22 Touch screen 66 1148 INTERIOR COMPONENTS 27 Blower Wheel 50 0408 28 Oven Element Cover 07 0242 DOOR COMPONENTS 29 Latch 50 1360 30 Catch 50 0421 31 Door Gasket 700 0083 A GENERAL EXTERIOR COMPONENTS 32 Side Access Panel 07 0222 33 Outside Top Solid back 07 0224 P...

Страница 20: ...RM RA SERIES OWNER S MANUAL NUVU MENOMINEE MICHIGAN 49858 page 18 SALES FAX 906 863 5889 SERVICE FAX 906 863 6322 906 863 4401 ...

Страница 21: ...RM RA SERIES OWNER S MANUAL NUVU MENOMINEE MICHIGAN 49858 906 863 4401 SALES FAX 906 863 5889 SERVICE FAX 906 863 6322 page 19 ...

Отзывы: