Triton
│
Installation and Operation Instructions - Boiler Piping
VS80-130
14
Figure 6-1 Near Boiler Piping
Central Heat
Domestic Hot Water
* Circulator location
may vary from one
application to another
Heating Return
Heating Supply
Inlet
Drain
Relief Valve
Water
Supply
Expansion Tank
Air Vent
Pump*
Bypass
(optional)
DHW to
Fixtures
Cold
Water
Supply
Drain Valve
(back flushing)
Unions
(for servicing)
Tempering Valve
(mandatory)
Isolation /
Throttle Valves
Coil Inlet
Coil Outlet