background image

NTI VEEMUX VIDEO MATRIX SWITCH 

 

36

 

Buttons 

 

The IRT-UNV Infrared Remote Control user interface consists of a keypad with 29 
buttons.  The buttons have the following functions: 

 

Numerical Values (0-9) 

ƒ

 

Selects port numbers (for IN, OUT) 

ƒ

 

Selects memory locations (for saved configurations) 

 

 

* (Asterisk) 

ƒ

 

Pressed to select all outputs 

 

 

OUT 

ƒ

 

Pressed to indicate an output port selection 

 

 

IN 

ƒ

 

Pressed to indicate an input port selection 

 

 

IN + / - 

ƒ

 

Cycles through input ports (up or down), connecting to each one (similar to 
changing channels) 

 

Note: This affects only the selected output port 
 

 

SAVE 

ƒ

 

Pressed to save the current switch configuration (port connections and 
volume settings) 

ƒ

 

Up to 10 configurations can be saved (0-9) 

 

 

RECALL 

ƒ

 

Pressed to recall a switch configuration (port connections and volume 
settings) 

ƒ

 

Up to 10 configuration can be recalled (0-9) 

 

 

SYS 

ƒ

 

Pressed to select the desired NTI system to be controlled 

ƒ

 

Only used when controlling multiple systems 

ƒ

 

Must be followed by a system number: 1-15 

 
 

 

ENTER 

ƒ

 

Pressed to immediately accept the command (normal delay is approx. 5 
seconds). 

 

 

ESC 

ƒ

 

Pressed to cancel the current command 

 

Note: If the command has not yet been accepted, all button presses in the 
command sequence will be cleared  

 

 

Standby 

               Pressed to put the unit into or out of standby mode 
 

 

VIDEO   

ƒ

 

Pressed prior to entering a port switch command 

ƒ

 

Applies the command to the video signals only 

ƒ

 

(by default, port switch commands are applied to both Audio and Video) 

 

 

BLANK Video 

ƒ

 

Turns OFF Video for the selected output 

ƒ

 

Can be used with *(Asterisk button) to turn OFF video for all outputs 

ƒ

 

Video will be turned ON by pressing the Blank Video button again, or by switching ports 

 

Note:  Blank and Un-Blank commands are applied only to the selected output 
 
 

Содержание SM-4X2-15V-LC

Страница 1: ...1 2012 SM nXm 15V LC Video Matrix Switch Installation and Operation Manual VEEMUX Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www network...

Страница 2: ...tted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of Network Technologies Inc 1275 Danner Drive Aurora Ohio 44202 CHANGES The...

Страница 3: ...2000 XP Vista and 7 13 SerTest RS232 Interface Test Program 14 Main Options 14 Matrix Operations 14 Ethernet Operations 14 Setup Options 15 Ethernet Control 16 Telnet Interface Port 2000 16 Telnet In...

Страница 4: ...ll Video Source Cables 5 Figure 4 Connect a monitor to the VEEMUX 5 Figure 5 Connect user terminal for RS232 control 6 Figure 6 Connect the LAN to the VEEMUX 6 Figure 7 Connect Power to VEEMUX 7 Figur...

Страница 5: ...ess of input RGsB monitor requires RGsB input Supported Web Browsers Most modern web browsers should be supported The following browsers have been tested Microsoft Internet Explorer 6 0 or higher Nets...

Страница 6: ...e male used for INPUTS 3 thru 100 feet Multi coax high resolution VGA or SVGA video cable Connectors are 15HD male female used for OUTPUTS 3 thru 100 feet Multi coax high resolution VGA to BNC cable C...

Страница 7: ...Illuminates to indicate communication between the hand held remote control and the VEEMUX 6 AC INPUT IEC Connector For attachment of the IEC power cord to power the VEEMUX 6a Fuse Fuseholder For repl...

Страница 8: ...ne up with the holes in the mounting ear on the NTI switch 3 Secure the NTI switch to the rack using four 10 32X3 4 screws supplied Each screw should be of sufficient length to go completely through t...

Страница 9: ...a video source to a 15HD female video connector labeled VIDEO 1 on the VEEMUX See Fig 1 3 Connect additional video sources to remaining 15HD female VIDEO x connectors as desired Figure 3 Install Video...

Страница 10: ...re 5 Connect user terminal for RS232 control Connect to the Ethernet If the Telnet Interface page 16 or Web Interface page 21 will be used an Ethernet connection to the Local Area Network LAN must be...

Страница 11: ...VIDEO MATRIX SWITCH 7 Power Up 1 Plug the VEEMUX into an AC power outlet 2 Turn ON power to the VEEMUX 3 Turn ON power to the video sources and monitors connected to the VEEMUX Figure 7 Connect Power...

Страница 12: ...to source 3 etc Along with the routing of the inputs video sources to the outputs monitors the keypad and LCD allow the users to configure the RS 232 control interface The keypad buttons perform the f...

Страница 13: ...re not used at this time and are therefore unnecessary 3 The third option in the main menu is Standby If you select Standby the VEEMUX switch will immediately go into a power saver mode and the LCD di...

Страница 14: ...on to most CPUs see page 6 To daisy chain multiple units connect a Matrix Y 1 cable sold separately between the CPU and the first switch and between each switch as shown in Figure 8 Baud Rate The baud...

Страница 15: ...D Female 9D Male 9D Male Wiring Schematic of Matrix Y 1 cable NTI SWITCH CPU RS232 First Unit NTI SWITCH RS232 NTI SWITCH RS232 Second Unit Last Unit RS232 Serial Port Matrix Y 1 Matrix Y 1 Matrix Y 1...

Страница 16: ...xx xxx format number of digits is minimum 1 and maximum 3 for each field Leading zeroes are accepted EM SW ip CR Set the Subnet mask ip is in xxx xxx xxx xxx format number of digits is minimum 1 and m...

Страница 17: ...es Message to the administrator will be delayed by any RS232 traffic being received by the switch from the administrator Autostatus must be disabled before using SerTest or the NTI Switch Control Prog...

Страница 18: ...bank c Change All Units Baud Rate 9600 COM1 change RS 232 Baud rate of all switches the current baud rate and serial port are displayed in parentheses d Reset Unit send a reset command to the switch...

Страница 19: ...ss current 1 select the unit address the current address is displayed in parentheses For any selection that requires user input the user is prompted When commands are sent to the matrix unit the comma...

Страница 20: ...prompted to introduce the password twice Change password CS nn mm CR Connect One Output User Port To Input Video source CA nn CR Connect All Outputs To Input RO nn CR mm CR Read Connection For Output...

Страница 21: ...rrent IP address at port 2005 Use the command set below to control and acquire information from the VEEMUX Note After establishing the connection the unit will answer with CR If the connection fails o...

Страница 22: ...Byte 6 Byte 7 Byte 8 Byte 9 p 0x70 c 0x63 Space 0x20 Output 1st digit 0x30 0x32 Output 2nd digit 0x30 0x39 0x2C Input 1st digit 0x30 0x32 Input 2nd digit 0x30 0x39 CR 0x0D This command will read the c...

Страница 23: ...x63 Space 0x20 Output 1st digit 0x30 0x32 Output 2nd digit 0x30 0x39 0x3A Input 1st digit 0x30 0x32 Input 2nd digit 0x30 0x39 CR 0x0D SS_00 Disable Auto Status Mode Command Byte 1 Byte 2 Byte 3 Byte 4...

Страница 24: ...he telnet session The unit is then available for future connections It is recommended that the XX command is used as it will close the Telnet connection with the server immediately If the XX command i...

Страница 25: ...dress into the address bar of the web browser Address To open a SSL encrypted connection type Address You will be prompted to accept a certificate Accept the NTI certificate A Login Page will appear F...

Страница 26: ...an be saved and later recalled by any connection method Scanning Sequences page 28 for each output can also be enabled Note Changes made using the keypad page 8 or by another user through the web inte...

Страница 27: ...e current connection selections the changes made by the other user will be saved as the configuration The webpage configuration that loads after a Save is the configuration that was actually saved To...

Страница 28: ...t Names Assign port names to each cable connection from display devices for easy reference Scanning Sequence Assign dwell times for each input as it is assigned to each output s scanning sequence Chan...

Страница 29: ...tion page Mode Choose between Static IP assignment and DHCP IP Address If using Static IP assignment enter a valid IP address to use Subnet Mask Enter a valid subnet mask value Default Gateway Enter a...

Страница 30: ...on will stay logged in The range is 0 3200 minutes 0 disables it Any change to the Website Timeout configuration takes effect immediately Press the Save button to save any changes made Video Input Nam...

Страница 31: ...ports displayed on the Switch page Figure 15 Video Output Names page To change an Output Name enter the name of the port for the desired output port number and press Save If you make changes and chan...

Страница 32: ...unt of time that each will be viewed 0 255 seconds can be set to cycle sequentially for each connected output If an input is set to 0 seconds that input will not be viewed and will be skipped from the...

Страница 33: ...ons and establish a connection and starting point for the scanning sequence Blocks shown in yellow in the third image indicate connections made 3 Click on the Sequence Enable box for each output from...

Страница 34: ...to change the password used to access the VEEMUX This password is also used for the telnet interface Be sure to make note of the new password exactly as it is case sensitive The password must be betwe...

Страница 35: ...rsion number and copy it to your computer 2 On the Update Firmware page in the Update File block browse to the firmware file 3 Press Upgrade Note If an update is attempted using the wrong firmware for...

Страница 36: ...e VEEMUX is placed in Standby Mode When in Standby Mode the VEEMUX is still operating as configured but cannot be manipulated further until standby is disabled Standby Mode can be disabled either by p...

Страница 37: ...Matrix Switch at NTI From there you can see what versions of firmware are available and determine if the version in your VEEMUX is current or in need of an upgrade page 31 Figure 21 Support Tab Reboo...

Страница 38: ...d display the Device Discovery Tool page Note The Discovery Tool requires the Java Runtime Environment to operate A link to the web page from which it can be downloaded and installed is provided on th...

Страница 39: ...es Routing of video and audio signals together or individually Ability to switch one input to all outputs Scroll through inputs for a single output by using the Input keys similar to changing channels...

Страница 40: ...and volume settings Up to 10 configuration can be recalled 0 9 SYS Pressed to select the desired NTI system to be controlled Only used when controlling multiple systems Must be followed by a system n...

Страница 41: ...s can be used to surf through input port connections However since there are multiple outputs users the question becomes which output connection is being changed As a result it is required that an out...

Страница 42: ...using the asterisk button which selects all outputs With the input port selected pressing the button will immediately force the command to connect all output ports to the selected input Example Connec...

Страница 43: ...address will illuminate the IR LED and respond to all IR Remote commands and will blink the IR LED on the front of the switch for visual indication All other switches will ignore any further commands...

Страница 44: ...x 1200 60Hz Video Signal Video Bandwidth Sync RGB analog 75 ohms 0 7 Vp p 160MHz typ or greater H V separated TTL composite sync on green Ethernet Connector RJ45 female 10BaseT RS232 Connector RJ45 f...

Страница 45: ...in no user serviceable parts In the event repair is needed all servicing must be performed by factory trained and authorized service personnel Only those items specifically identified in this manual i...

Страница 46: ...two 2 years from the date of purchase Please contact Network Technologies Inc at 800 742 8324 800 RGB TECH or 330 562 7070 or visit our website at http www networktechinc com for information regardin...

Отзывы: