With the dialer in a programming state: press 

6

 to input alarm dialing times (0-9), press  "ENTER

.  

If 

 displays it means the input was correct, and the dialer will return to state 

5

 
Program how many times dialing should be repeated during an alarm state 

(initial setting is 5 times) 

0= unlimited dialing; 
1-9: repeat dialing 1-9 times 
 
To find out how times the dialer is programmed to repeated dialing:  
While in a programming state, press 

3

 and then 

6

the 7-segment display will show the number of times it is programmed to repeat dialing, and then you will hear a 

Du

 
Note: for SMS alarm methods,  the dialer will stop sending the message if the message is sent successfully.  It is  
not ruled by the programmed number of repeat dialing times. 
 
 

8. 

Save and 

Check

 password: 

 

To store a password (Initial password is 0911): the dialer supports a 4-digit private password. 
 If the private password will be 1234, while operating in a programming state:  
press 

PAUSE

1

 

2

 

3

 

4

ENTER

 and hear a tone 

Du

 which means the input is finished 

(the password must be 4 digits, if less than 4 digits, system will display 

E

 and enter state 

5

.. 

 
Inquire password; in programming state (state 

5

), press 

3

 and then 

PAUSE

, monitor display password, and hear a 

tone 

Du

 after display is done. 

 
Note: If user loses the password, they can open the back cover of the dialer, power the Dialer ON,  and press the 

RESET BUTTON" (see page 2).  Password will be changed to the default one: 0911,  but all other programmed 

information (data) will not be lost. 
 

CAUTION: TO PRESS THE RESET BUTTON,  INSERT A NON-CONDUCTIVE MATERIAL BETWEEN THE 
CIRCUIT BOARDS WHILE THE UNIT IS ON AND PRESS THE BUTTON.   USING A CONDUCTIVE 
MATERIAL MAY SHORT THE CIRCUIT BOARD AND DAMAGE YOUR DIALER,  VOIDING THE 
WARRANTY.    

 

9. 

Program and 

Check

 alarm trigger delay 

 

You can control the delay time that the trigger must be present before the dialer will go into an alarm state and begin 
dialing.  

 

In programming state, press 

7

 and enter the triggering delay (0=0.5 second

1=1 second, 2=2 seconds

.....9=9 

seconds), and then press 

ENTER

.  

If 

 is displayed it means the input is correct and it will return to state 5. 

 
To determine the presently programmed delay time:     
In programming state, press 

3

 and 

7

 , 

The  7-segment display will show triggering time , followed by a tone 

Du

 
Note: the default trigger delay time is 0.5 second. 
 
 
10. Stop Alarm Dialing on Dialer. 

While triggered, the AUTO DIALER will automatically alarm by dialing the numbers saved. If a user wants to stop it, input 
private code while 

0

 displayed. Suppose code is 1234, 

1234

 will be displayed instead of 

0

 after input. If the code is 

correct, the alarm will be withdrawn followed by the 

Du

…”

sound, 

and the dialer will return to 

standby mode. 

 
The User must input the 4 digit password correctly.  An incorrect password will fail to withdraw the alarm.   
 
 

Содержание E-AVDS-4G1

Страница 1: ...range of a configurable threshold o Mini SIM card supporting SMS messaging required not included Stores one outgoing voice message of up to 20 seconds and sends one SMS message of up to 70 bytes E AV...

Страница 2: ...n and to access the mounting holes you must first open the case of the dialer There are four tabs that hold the case together Two on the top side and two on the bottom side To open the case for jumper...

Страница 3: ...et the normal relay state to Normally Closed apply the J1 and J2 jumpers to the center and left pins In this configuration a relay open condition will trigger an alert state activating the dialer CAUT...

Страница 4: ...Connect the cable from the E AVDS 4Gx to the E xD according to one of the following diagrams Note The attached cable is 700mm 27 inches long but can be extended up to 100 feet with any 3 conductor 22A...

Страница 5: ...5...

Страница 6: ...ator OFF FULL NETCOM module is powered OFF or not working 200ms ON and 200ms OFF data communication built 800ms ON and 800ms OFF network register successful LED indicator ON sending alarm or data comm...

Страница 7: ...1 ENTER If the password you entered in is correct the LED will display 5 and then log into the Programming Mode If the password you entered is incorrect the LED will display E and return to the workin...

Страница 8: ...s begin recording and then begin talking and recording after which you will hear Du The dialer will stop automatically and playback the voice message after it has finished recording The User can stop...

Страница 9: ...s the password they can open the back cover of the dialer power the Dialer ON and press the RESET BUTTON see page 2 Password will be changed to the default one 0911 but all other programmed informatio...

Страница 10: ...ialization the alarm will not be sent 2 Press ENTER to return to working state after finishing an operation If ENTER is not pressed and the LED displays 5 programming state it will lead to alarm commu...

Страница 11: ...140 F 4 to 60 C Dimensions WxDxH 5 87x3 54x1 25 in 149x90x32 mm Included Antenna dimensions WxDxH 1 18x1 18x3 9 in 30x30x99 mm Part Supported Country Supported Bands Supported Frequencies in MHz FDD L...

Отзывы:

Похожие инструкции для E-AVDS-4G1