background image

 
 

 
A

UTO-DIALER OPERATION 

 

 

Power ON 

Self-

T

est: 

The Dialer will perform a self-test checking signal connection when powered ON.   After the self-test, if a connection is 
made the number on the display will indicate the signal strength (1 = weak,  5 = strong), the decimal point at the lower 
right corner on the 7 segment display will blink slowly and the dialer will be ready to work.   
 

Note: If no signal is found, the decimal point will blink rapidly and "0" will be displayed.  

 
If configuration (phone numbers and voice message) already exists, the AUTO-DIALER will alarm automatically upon 
receiving an alarm signal.   To setup or change the configuration, please follow the procedures below to save and check 
telephone numbers and passwords as well as to record and play back recorded voice message: 
 

1. Log into the Programming Mode: 

 
First press 

P

AUSE

 , then put in the Private Password (4 digits), then press 

ENTER

 

Note: The Default Password is 

0

911 

 

For instance: Log into the Programming Mode as follows: 
PAUSE 0911 ENTER 
 
If the password you entered in is correct, the LED will display "

5

", and then log into the Programming Mode, 

 
If the password you entered is incorrect, the LED will display “E

” 

and return to the working mode.     Repeat the 

procedure to try again. 
 

2.  Program and 

Check

 SMS 

C

enter 

N

umber 

 
If you do not program the SMS Center number (your carrier's connection number) after powering ON the dialer, it will 
automatically obtain the number by default.  
 

We recommend to allow the dialer to automatically obtain SMS center number in normal use. 

 
To view the current SMS Center number: Under programming state (in

5

state): press 

3

 and 

0

; the dialer will display 

the SMS Center number, and user will hear a tone 

Du

.    If the number is not correct, perform the following to change it: 

 

Under programming state (

 

"5

on the display): press 

0

 and then input SMS center number, and press 

ENTER

. (You 

will need to get this number from your carrier if the dialer does not obtain the number automatically)    
 
 For example: 0+18965713028=ENTER.      
 
The dialer will display 

if it receives a correct input. 

 
To delete the SMS center number: under programming state, press 

0

 and then

ENTER

. The dialer will display "

 if it 

receives a correct input.  
 

 

 
 
 
 
 
 
 
 

 
 
 

Содержание E-AVDS-4G1

Страница 1: ...range of a configurable threshold o Mini SIM card supporting SMS messaging required not included Stores one outgoing voice message of up to 20 seconds and sends one SMS message of up to 70 bytes E AV...

Страница 2: ...n and to access the mounting holes you must first open the case of the dialer There are four tabs that hold the case together Two on the top side and two on the bottom side To open the case for jumper...

Страница 3: ...et the normal relay state to Normally Closed apply the J1 and J2 jumpers to the center and left pins In this configuration a relay open condition will trigger an alert state activating the dialer CAUT...

Страница 4: ...Connect the cable from the E AVDS 4Gx to the E xD according to one of the following diagrams Note The attached cable is 700mm 27 inches long but can be extended up to 100 feet with any 3 conductor 22A...

Страница 5: ...5...

Страница 6: ...ator OFF FULL NETCOM module is powered OFF or not working 200ms ON and 200ms OFF data communication built 800ms ON and 800ms OFF network register successful LED indicator ON sending alarm or data comm...

Страница 7: ...1 ENTER If the password you entered in is correct the LED will display 5 and then log into the Programming Mode If the password you entered is incorrect the LED will display E and return to the workin...

Страница 8: ...s begin recording and then begin talking and recording after which you will hear Du The dialer will stop automatically and playback the voice message after it has finished recording The User can stop...

Страница 9: ...s the password they can open the back cover of the dialer power the Dialer ON and press the RESET BUTTON see page 2 Password will be changed to the default one 0911 but all other programmed informatio...

Страница 10: ...ialization the alarm will not be sent 2 Press ENTER to return to working state after finishing an operation If ENTER is not pressed and the LED displays 5 programming state it will lead to alarm commu...

Страница 11: ...140 F 4 to 60 C Dimensions WxDxH 5 87x3 54x1 25 in 149x90x32 mm Included Antenna dimensions WxDxH 1 18x1 18x3 9 in 30x30x99 mm Part Supported Country Supported Bands Supported Frequencies in MHz FDD L...

Отзывы: