11
SPECIFICATIONS
Voltage
DC 11V to 15V
Static current
60mA (Based on operating voltage: DC 12V)
Operating current
350mA (MAX) (Based on operating voltage: DC 12V)
Power Source
Powered by the E-2D/5D/16D unless "-P" model;
"-P" model includes 12VDC 1A AC Adapter
Triggering mode
N.C
or
N.O
Voice recording
20 seconds maximum; phone numbers and voice message will be
saved after power off
Phone numbers
Up to 8 , 16 digits maximum
Private password protection
4-digit private password programmable
Default password = 0911
SMS Support
system supports SMS message alarm (70 characters maximum)
Operating Temperature
39 to 140
°
F (4 to 60
°
C)
Dimensions (WxDxH)
5.87x3.54x1.25 in (149x90x32 mm)
Included Antenna
dimensions (WxDxH)
1.18x1.18x3.9 in (30x30x99 mm)
Part #
Support
ed
Country
Support
ed
Band
s
*
Supported Frequencies (in MHz)
FDD-LTE: B2/B4/B12
1900/1700/700
E-AVDS-4G1
North America (AT&T)
WCDMA: B2/B5
1900/850
FDD-LTE: B1/3/5/7/8/20
2100/1800/850/2600/900/800
TDD-LTE: B38/40/41
2600/2300/2500
WCDMA: B1/5/8
2100/850/900
E-AVDS-4G3 Europe
/ Middle East /
Africa / South Korea /
Thailand
GSM 900/1800
FDD-LTE: B1/3/4/5/7/8/28
2100/1800/1700/850/2600/900/700
TDD-LTE: B40
2300
WCDMA: B1/2/5/8
2100/1900/850/900
E-AVDS-4G4 New
Zealand / Australia /
South America
GSM 850/900/1800/1900
*Check with your service provider to determine what band(s) must be supported by your dialer for your area to determine
what model is right for you.