INTRODUCTION 

 

The E-AVDS-4Gx (x- 1,2 or 3) 4G Automatic Voice and SMS Dialer is used to send voice alert or SMS messages from 
an ENVIROMUX Enterprise Environment Monitoring System to any user’s cell phone or device capable of receiving voice 
or SMS messages.   
 
The E-AVDS-4Gx-

P

 includes a 12VDC power supply for connection to E-MINI-LXO, E-DI16DOR16 or any other 

Enterprise Environment Monitoring System where an external power supply will be needed.  

 

 

Features 

 

Ideal for remote places without conventional phone lines. 

 

Calls or sends SMS to up to 8 telephone or cell phone numbers when a sensor goes out of range of a 
configurable threshold. 

o

 

Mini SIM card supporting SMS messaging required (not included). 

 

Stores one outgoing voice message of up to 20 seconds and sends one SMS message of up to 70 bytes. 

 

E-AVDS-4G1 

o

 

4G LTE network band: FDD B2/4/12 

o

 

3G network band: WCDMA B2/5 

 

E-AVDS-4G3 

o

 

4G LTE network band: FDD B1/3/5/7/8/20, TDD B38/40/41 

o

 

3G network band: WCDMA B1/5/8 

o

 

2G network band: GSM 900/1800MHz 

 

E-AVDS-4G4 

o

 

4G LTE network band: FDD B1/2/3/4/5/7/8/28, TDD B40 

o

 

3G network band: WCDMA B1/2/5/8 

o

 

2G network band: GSM 850/900/1800/1900MHz 

 

Interfaces with the E-2D/5D/16D via the Output Relay connections. 

 

Powered by the E-2D/5D/16D. 

 

Maximum current: 350mA @ 12VDC 

 

Dimensions WxDxH: 5.87x3.54x1.25 in (149x90x32 mm) 

o

 

Included Antenna dimensions WxDxH: 1.18x1.18x3.9 in (30x30x99 mm) 

 

Operating temperature: 39 to 140

°

F (4 to 60

°

C) 

 

For normally closed or normally open circuit connections. 

 
 
 
 
 
 
 
 

Содержание E-AVDS-4G1

Страница 1: ...range of a configurable threshold o Mini SIM card supporting SMS messaging required not included Stores one outgoing voice message of up to 20 seconds and sends one SMS message of up to 70 bytes E AV...

Страница 2: ...n and to access the mounting holes you must first open the case of the dialer There are four tabs that hold the case together Two on the top side and two on the bottom side To open the case for jumper...

Страница 3: ...et the normal relay state to Normally Closed apply the J1 and J2 jumpers to the center and left pins In this configuration a relay open condition will trigger an alert state activating the dialer CAUT...

Страница 4: ...Connect the cable from the E AVDS 4Gx to the E xD according to one of the following diagrams Note The attached cable is 700mm 27 inches long but can be extended up to 100 feet with any 3 conductor 22A...

Страница 5: ...5...

Страница 6: ...ator OFF FULL NETCOM module is powered OFF or not working 200ms ON and 200ms OFF data communication built 800ms ON and 800ms OFF network register successful LED indicator ON sending alarm or data comm...

Страница 7: ...1 ENTER If the password you entered in is correct the LED will display 5 and then log into the Programming Mode If the password you entered is incorrect the LED will display E and return to the workin...

Страница 8: ...s begin recording and then begin talking and recording after which you will hear Du The dialer will stop automatically and playback the voice message after it has finished recording The User can stop...

Страница 9: ...s the password they can open the back cover of the dialer power the Dialer ON and press the RESET BUTTON see page 2 Password will be changed to the default one 0911 but all other programmed informatio...

Страница 10: ...ialization the alarm will not be sent 2 Press ENTER to return to working state after finishing an operation If ENTER is not pressed and the LED displays 5 programming state it will lead to alarm commu...

Страница 11: ...140 F 4 to 60 C Dimensions WxDxH 5 87x3 54x1 25 in 149x90x32 mm Included Antenna dimensions WxDxH 1 18x1 18x3 9 in 30x30x99 mm Part Supported Country Supported Bands Supported Frequencies in MHz FDD L...

Отзывы: