Installation and connection of HC10B 
Remove the front cover from the display by inserting a small screwdriver in the square hole on top of the thermostat. At the same 
time, carefully lift the front cover outwards. Then remove the frame. 
 
Connect wires and sensors to HC10B in accordance with the diagram. 
Connection must be made by an authorised electrician. 
Important! See section, 

“Starting up underfloor heating with HC10B”, before turning on the power. 

 
Replace the frame and press on the cover. Activate the lock with a click. 